On the reliability and standard errors of measurement of contrast measures from the D-KEFS.
نویسندگان
چکیده
A formula for the reliability of difference scores was used to estimate the reliability of Delis-Kaplan Executive Function System (D-KEFS; Delis et al., 2001) contrast measures from the reliabilities and correlations of their components. In turn these reliabilities were used to calculate standard errors of measurement. The majority of contrast measures had low reliabilities: of the 51 reliability coefficients calculated in the present study, none exceeded 0.7 and hence all failed to meet any of the criteria for acceptable reliability proposed by various experts in psychological measurement. The mean reliability of the contrast scores was 0.27, the median reliability was 0.30. The standard errors of measurement were large and, in many cases, equaled or were only marginally smaller than the contrast scores' standard deviations. The results suggest that, at present, D-KEFS contrast measures should not be used in neuropsychological decision making.
منابع مشابه
Test-Retest Reliability of Dynamic Postural Stability Measures in Healthy and Chronic Non-specific Low Back Pain Groups
Objective: The primary aim of the present study was to study the reliability of postural stability measures during whole body dynamic conditions, so they can be used in postural stability evaluations, investigations of injury mechanisms and assessments of treatment efficacy. Materials & Methods: Twelve healthy volunteers and 12 low back pain patients performed repeated trunk bending motions ...
متن کاملThe Reliability of Postural Balance Measures in Single and Dual Tasking in Healthy Elders
Objectives: The present study aimsed to examine the reliability of forceplate parameters under both single and dual task conditions and in different levels of postural difficulty. Methods & Materials: The healthy elderly+65, were assessed with aone-week interval, with a random combination of three levels of postural difficulty (i.e., standing on a rigid surface with eyes open, standing on a ...
متن کاملTest-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
Abstract Background: Postural instability has been identified as a potential precursor of falls in elderly subjects. Postural stability in quiet stance is commonly assessed with center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure (COP) measures in the elderly subjects. Met...
متن کاملThe Effect of Gauge Measurement Capability and Dependency Measure of Process Variables on the MCp
It has been proved that process capability indices provide very efficient measures of the capability of processes from many different perspectives. These indices have been widely used in the manufacturing industry for measuring process reproduction capability according to manufacturing specifications. In the past few years, univariate capability indices have been introduced and used to characte...
متن کاملPrediction of ADHD in boys and girls using the D-KEFS.
To examine patterns of executive dysfunction associated with ADHD, 123 children (54 ADHD, 69 controls) of ages 8-16 years were administered selected subtests from the Delis-Kaplan Executive Function System (D-KEFS). Children with ADHD performed significantly worse than controls on measures of both basic (less executive demand) skills and those with more executive demand from the Color-Word Inte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the International Neuropsychological Society : JINS
دوره 14 6 شماره
صفحات -
تاریخ انتشار 2008