A test of the practical value of estimating breath sound intensity. Breath sounds related to measured ventilatory function.
نویسندگان
چکیده
Each of four examiners performed standardized physical examinations on a group of patients who had just undergone tests of ventilatory function. The intensity of breath sounds heard with deep inspiration was graded on a rating scale of 0 to 4; the grades in six areas of the chest were added to give a total score, with possible values ranging from 0 to 24. Correlation of breath-sound scores with percentage of predicted forced expiratory volume in one second (FEV1) was significant at the 1 percent level for all of the examiners. Differences between the examiners in their assessment of breath sounds were not statistically significant. Grading the loudness of breath sounds was a poor screening test for mild ventilatory abnormality, but normal breath sounds nearly excluded the possibility of severe reduction in the FEV1. Definitely reduced breath-sound intensity was strong evidence for the presence of obstructive pulmonary disease.
منابع مشابه
Potential for lung sound monitoring during bronchial provocation testing.
BACKGROUND The use of lung sound monitoring during bronchial provocation testing has not been clearly demonstrated. The appearance of wheeze and changes in inspiratory breath sound intensity have been analysed and related to changes in spirometric parameters and to airways hyperresponsiveness. METHODS Lung sounds were recorded in 38 patients undergoing a routine carbachol airway challenge (CA...
متن کاملInitiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran
Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...
متن کاملChanges in frequency spectra of breath sounds during histamine challenge test in adult asthmatics and healthy control subjects.
Air-flow standardized breath sounds were recorded at the chest and at the trachea during histamine challenge test and after subsequent bronchodilation in 12 asthmatics and 6 healthy controls for spectral analysis, to be compared with simultaneous changes in spirometric variables. Of all the lung sound variables measured, the changes in median frequency of the power spectrum (F50) of tracheal ex...
متن کاملAuditory detection of simulated crackles in breath sounds.
BACKGROUND Computerized analysis of breath sounds has relied on human auditory perception as the reference standard for identifying crackles. In this study, we tested the human audibility of crackles by superimposing artificial clicks on recorded breath sounds and having physicians listen to the recordings to see if they could identify the crackles. OBJECTIVES To establish the audibility of s...
متن کاملSignificant differences in flow standardised breath sound spectra in patients with chronic obstructive pulmonary disease, stable asthma, and healthy lungs.
BACKGROUND Spectral characteristics of breath sounds in asthma and chronic obstructive pulmonary disease (COPD) have not previously been compared, although the structural differences in these disorders might be reflected in breath sounds. METHODS Flow standardised inspiratory breath sounds in patients with COPD (n = 17) and stable asthma (n = 10) with significant airways obstruction and in co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 70 03 شماره
صفحات -
تاریخ انتشار 1976