Use of flexible plastic film isolators in performing potentially hazardous necropsies.

نویسندگان

  • P C Trexler
  • A M Gilmour
چکیده

A number of necropsies were performed with the body completely isolated in a flexible film isolator in order to determine the practicability of such a method in protecting the post mortem room staff from the risk of infection from the corpse. It is considered that necropsies can be carried out using such an isolator without hindrance to either manual skill or vision and that a high degree of safety is achieved. The isolator may also be used to carry out necropsies on decomposed bodies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving seismic performance of elevated cylindrical water storage tanks using nonlinear isolators incorporating liquid–structure interaction

Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the necessity for research toward new passive control devices. Design and use of base-isolation systems for elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relati...

متن کامل

Earthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction

A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...

متن کامل

Earthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction

A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...

متن کامل

InN Based Water Condensation Sensors on Glass and Flexible Plastic Substrates

In this paper, we report the realization and characterization of a condensation sensor based on indium nitride (InN) layers deposited by magnetron sputtering on glass and flexible plastic substrates, having fast response and using potentially low cost fabrication technology. The InN devices work as open gate thin film sensitive transistors. Condensed water droplets, formed on the open gate regi...

متن کامل

Should eye protection be worn when performing necropsies?

One hundred necropsies were performed by four junior pathologists wearing safety spectacles. The number of blood splashes on the spectacle surfaces were counted after each necropsy. Splashes were found after 22 necropsies (range 10-34%), with higher numbers being seen among the more junior grades of pathologist. This suggests that the use of safety spectacles should be considered by all patholo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 1983