High sensitive approach for point mutation detection based on electrochemiluminescence.
نویسندگان
چکیده
An electrochemiluminescence-polymerase chain reaction (ECL-PCR) method for point mutation detection has been developed. The target is amplified using a tris (bipyridine) ruthenium (TBR)-labeled forward and a biotinylated reverse primer. The amplification products are digested with specific restriction enzyme, then captured onto streptavidin-coated paramagnetic beads, and detected by measuring the ECL signal of the TBR label. The established technique was further applied to detect a specific point mutation in H-ras oncogene in T24 cell line. The results show that the system has a low detection limit of 100 fmol and a linear range of more than 3 orders of magnitude for H-ras amplicon; the two genotypes can be reliably discriminated. In summary, the mutant specific ECL-PCR method can be used to detect a point mutation that creates or destroys a restriction site in any gene. It is useful in single nucleotide polymorphism (SNP) and mutation detection due to its safety, high sensitivity and simplicity.
منابع مشابه
Detection of Clindamycin in Pharmaceutical Products using an Electrochemiluminescence Electrode based on a Composite of Ru(bpy)3²+, Eu2O3 Nanoparticle and Chitosan
In this study, the electrochemiluminescence (ECL) interaction of clindamycin and tris(2,2′-bipyridine)ruthenium(II) (Ru(bpy)32+) was used to develop a sensitive tool for the detection of clindamycin based on modifying a glassy carbon electrode (GCE) with nanoparticles of europium oxide. The experiments showed that in the presence of these inorganic nanoparticles (Eu2<...
متن کاملHighly sensitive detection of protein and small molecules based on aptamer-modified electrochemiluminescence nanoprobe.
Amplified optical detection of biomolecules using nanoparticle as the carrier has attracted considerable interest in the scientific community. In this study, a promising aptasensor was developed for highly sensitive detection of protein and small molecules based on the construction of aptamer-modified electrochemiluminescence (ECL) nanoprobe. Specifically, thrombin and ATP serve as the examples...
متن کاملThe Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography
Background: Several methods have been developed for detection of sequence variation in genes and each has its advantages and disadvantages. A disadvantage of them is that the simpler, cost-effective methods are commonly perceived as being less sensitive in their detection of sequence variation, whereas those with proven sensitivity have a requirement for complex or expensive laboratory equipmen...
متن کاملElectrochemiluminescence energy transfer-promoted ultrasensitive immunoassay using near-infrared-emitting CdSeTe/CdS/ZnS quantum dots and gold nanorods
The marriage of energy transfer with electrochemiluminescence has produced a new technology named electrochemiluminescence energy transfer (ECL-ET), which can realize effective and sensitive detection of biomolecules. To obtain optimal ECL-ET efficiency, perfect energy overlapped donor/acceptor pair is of great importance. Herein, we present a sensitive ECL-ET based immunosensor for the detecti...
متن کاملDetection of ozone based on its striking inhibition of tris(1,10-phenanthroline)ruthenium(II)/glyoxal electrochemiluminescence.
Ozone unexpectedly dramatically suppresses the electrochemiluminescence (ECL) of Ru(phen)3(2+)/glyoxal at an ozone/glyoxal ratio of less than 0.5%. Moreover, a sensitive, simple and fast ECL method for ozone detection is developed, with a detection time within 1 min and a limit of detection of 20 nM.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 20 3 شماره
صفحات -
تاریخ انتشار 2004