Active length of cable lines with uncoated metal sheaths as long grounding conductors
نویسنده
چکیده
Power cables that have sheaths, usually lead, and are manufactured with bitumen impregnated hessian which degrades over time, act as long grounding electrodes or inject fault current directly into the surrounding soil. As a consequence of this, the MV lines made of this type of cable spontaneously form a very large and complex grounding system around the high-voltage/medium-voltage (HV/MV) distribution substations. The area encompassed by this type of grounding system is much larger than the area occupied by the HV/MV substation itself. Due to this, the grounding system exhibits excellent performance, including a very low value of impedance to ground. The problem with this type of grounding system appears only at the design stage of the HV/MV substation, when safety conditions inside and in the vicinity of this substation should be confirmed by calculation. This paper provides improvements in accuracy to the only existing practical method developed for the analysis of this type of grounding system. The proposed improvement enables a more accurate estimation of active cable line length, grounding impedance of the cable line, the urban area covered by this type of grounding system, as well as grounding impedance of the entire grounding system. Copyright # 2010 John Wiley & Sons, Ltd.
منابع مشابه
Electrical and Thermal Analysis of Single Conductor Power Cable Considering the Lead Sheath Effect Based on Finite Element Method
This paper investigates the effect of metallic sheaths on losses and temperature of medium voltage power cables. Two grounding methods of sheaths, including both ends bonding and single point bonding that causes different situations on cable ampacity, are considered. Electrical losses of cables that are main sources of heat are calculated in both conductor and metallic sheath of the cables. She...
متن کاملCalculation of earthing and screening effects of compensation conductor laid alongside underground multi-cable power lines
Power substations in an urban area are interconnected by high voltage underground power cables, resulting also in interconnections of their earthing grids through cable metallic screens/sheaths. Most modern power cables with XLPE insulated core have metallic screens which are practically insulated from ground. These screens can only be (and usually are) grounded at cable ends and therefore do n...
متن کاملImpact of introducer sheath coating on endothelial function in humans after transradial coronary procedures.
BACKGROUND The aim of this study was to compare the impact of transradial catheterization with hydrophilic-coated catheter sheaths versus uncoated sheaths on NO-mediated endothelial-dependent and -independent vasodilator function. METHODS AND RESULTS Thirty-five subjects undergoing transradial catheterization were recruited and assessed before and the day after catheterization. A subgroup was...
متن کاملReturn to Session THE USE OF INSULATED WIRES MILLIKEN CONDUCTORS IN HIGH VOLTAGE POWER TRANSMISSION UNDERGROUND AC LINES
These last years have pointed out a significant increase of the power that needs to be transported by underground power cables. As a consequence, large cross section conductors, up to 2500mm2 are now customarily used. The CIGRE group B1-03 has completed in 2005 a work that analyses the actual AC resistance of these large cross section conductors as a function of their design. The authors discus...
متن کاملInduced Disturbance Voltages in Isolated Conductors Situated in Close Vicinity of a Inducing High Voltage Cable Line
Mutual inductive interferences occur between electrical systems that are located in close vicinity over a certain distance so that the low frequent electromagnetic field can interact between the galvanic isolated systems. Especially in urban regions so-called energy corridors are built where high voltage power lines are often situated close to information and telecommunication lines, other powe...
متن کامل