Effect of repeated through-and-through joint lavage on serum amyloid A in synovial fluid from healthy horses.

نویسندگان

  • A F Sanchez-Teran
  • J L Bracamonte
  • S Hendrick
  • L Riddell
  • K Musil
  • B Hoff
  • L M Rubio-Martínez
چکیده

The objective of this study was to evaluate the effect of through-and-through joint lavage on systemic and synovial serum amyloid A (SAA), total protein, nucleated cell count and percentage of neutrophils in the synovial fluid of six healthy horses. A prospective experimental study was performed where one healthy tarsocrural joint of each horse was randomly assigned to receive repeated through-and-through joint lavage at 0, 48 and 96 h. Synovial fluid and blood samples were collected at 0 (baseline), 24, 48, 72, 96 and 120 h. Systemic and synovial SAA, total protein, nucleated cell count and percentage of neutrophils were measured and compared to baseline. Concentrations of systemic and synovial SAA percentage of neutrophils were not increased from baseline in contrast to total protein and nucleated cell counts (except for nucleated cell count at 96 h). In conclusion, repeated through-and-through joint lavage did not affect synovial SAA concentrations in horses; however, synovial total protein and nucleated cell count values increased. Some of the total protein and nucleated cell count values observed in this study were within the range reported for septic arthritis 24 h after joint lavage. Hence, synovial SAA may be a valuable marker to evaluate the clinical progression of septic joints after through-and-through joint lavage. Clinical studies evaluating synovial fluid SAA concentrations while treating synovial sepsis with through-and-through joint lavage are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

14-3-3  Protein is Detectable in Blood Serum and Fetlock Joint Synovial Fluid of High Performance Horses

Objective: To investigate whether 14-3-3 eta protein is detectable in synovial fluid and blood serum of high performance horses and to study whether any significant correlation between this and matrix metalloproteinase 1 and 3 in horse synovial fluid. Design: Clinical study. Animals: Eleven standard breed horses (seven high performances and four controls). Procedures: Blood serum and fetlock...

متن کامل

Synovial fluid inflammatory cytokines and proteins in clinically healthy and arthritic joint of dromedary camels (Camelus dromedarius)

Analyzing the synovial fluid is one of the common methods to diagnose the articular problems to detect the stage and express the prognosis. Such gross, cytological, and biochemical analysis of synovial fluids can aid in the diagnosis of various joint diseases. Objectives: Normal values for synovial fluid in the camels have been described previously; however, there are no reports regarding conce...

متن کامل

Concentration of the CS-846 Epitope in Serum and Synovial Fluid of Horses with Different Grades of Osteochondral Fragments in the Carpal Joints

The aim of this study was to determine serum and synovial concentrations of the CS-846 epitope of articular cartilage aggrecan, in horses with a radiological diagnosis of osteochondral fragmentation (OF). For this purpose, 20 thoroughbred horses with unilateral radiocarpal or intercarpal OF were used, and 10 clinically and radiologically healthy Thoroughbred horses were assigned to the control ...

متن کامل

Apolipoprotein-A1 as a Damage-Associated Molecular Patterns Protein in Osteoarthritis: Ex Vivo and In Vitro Pro-Inflammatory Properties

Osteoarthritis (OA) is associated with a local inflammatory process. Dyslipidemia is known to be an underlying cause for the development of OA. Therefore, lipid and inflammatory levels were quantified ex vivo in blood and synovial fluid of OA patients (n=29) and compared to those of rheumatoid arthritis (RA) patients (n=27) or healthy volunteers (HV) (n=35). The role of apolipoprotein A-I (ApoA...

متن کامل

Morphine Synovial Fluid Concentrations After Intravenous Regional Limb Perfusion in Standing Horses.

OBJECTIVE To determine synovial concentrations of morphine after intravenous regional limb perfusion (IVRLP) with morphine or morphine in combination with gentamicin in clinically healthy, standing sedated horses. STUDY DESIGN Experimental. ANIMALS Adult horses (n = 6). METHODS IVRLP was performed using 0.1 mg/kg morphine (M) in standing sedated horses. After a 3-week washout period, IVRL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary journal

دوره 210  شماره 

صفحات  -

تاریخ انتشار 2016