In vitro pyrogen test--A new test method for solid medical devices.

نویسندگان

  • Francesca Mazzotti
  • Julia Beuttler
  • Richard Zeller
  • Ulrich Fink
  • Stefanie Schindler
  • Albrecht Wendel
  • Thomas Hartung
  • Sonja von Aulock
چکیده

Medical devices manufactured for implantation into humans must be free of any contamination with viable bacteria. However, remnants of dead bacteria and bacterial components alone may induce an inflammatory immune response. Pyrogen tests for such inflammatory contaminations are generally performed either by determining the content of lipopolysaccharide in rinsing solutions of batch samples by limulus amoebocyte lysate assay, by injecting the rinsing solutions into rabbits or by implanting batch samples into rabbits and measuring change of body temperature. In this study, we show that the in vitro pyrogen test (IPT), which measures the release of the inflammatory cytokine IL-1beta in fresh or cryopreserved human whole blood, can be used to assess the pyrogenic contamination of implantable medical devices. This test was used to check neurosurgical implants, namely aneurysm clips, as a proof of principle. Owing to the direct contact of the test material with the blood cells, this test does not require rinsing procedures, which have variable efficacy. The use of human blood ensures the detection of all substances that are pyrogenic for humans and reflects their relative potency. The safety of the products as delivered could be confirmed. The effects of sterilization and depyrogenization procedures on intentional pyrogenic contaminations of samples could be followed. This new application of the already internationally validated method promises to replace further rabbit pyrogen tests. It generates extremely sensitive results with an extended range of detectable pyrogenic contaminants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro pyrogen test for toxic or immunomodulatory drugs.

Pyrogenic contaminations of some classes of injectable drugs, e.g. toxic or immunomodulatory as well as false-positive drugs, represent a major risk which cannot yet be excluded due to the limitations of current tests. Here we describe a modification of the In vitro Pyrogen Test termed AWIPT (Adsorb, Wash, In vitro Pyrogen Test), which addresses this problem by introducing a pre-incubation step...

متن کامل

Endotoxin Detection in Pharmaceuticals and Medical Devices with Kinetic-QCL, a Kinetic-Quantitative Chromogenic Limulus Amebocyte Lysate Assay.

The observation that endotoxin caused gelation in extracts of Limulus amebocytes has been expanded to the development of an in vitro kinetic, quantitative chromogenic LAL assay (Kinetic-QCL) for the detection of endotoxin in aqueous fluids. Within the last 15 years, the use of Limulus amebocyte lysate to detect and control the presence of pyrogenic substances in pharmaceuticals and medical devi...

متن کامل

Development, validation and applications of the monocyte activation test for pyrogens based on human whole blood.

Microorganisms such as Gram-negative or Gram-positive bacteria, viruses and fungi contain components that activate the innate immune system. These components, called pyrogens (Greek: pyros=fire), can occur independently of viable microorganisms and are a major safety concern in parenterally administered drugs, since they can cause severe reactions such as fever, organ failure, and shock in the ...

متن کامل

The human whole blood pyrogen test - lessons learned in twenty years.

The whole blood pyrogen test was first described in this journal exactly twenty years ago. It employs the cytokine response of blood monocytes for the detection of microbiological contaminants with the potential to finally replace the still broadly used rabbit pyrogen test. The article reviews its development process, the current status of the test as well as the challenges and missed opportuni...

متن کامل

Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test

The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part A

دوره 80 2  شماره 

صفحات  -

تاریخ انتشار 2007