Continuous glucose monitoring in preterm infants: evaluation by a modified Clarke error grid.

نویسندگان

  • Eloisa Tiberi
  • Francesco Cota
  • Giovanni Barone
  • Alessandro Perri
  • Valerio Romano
  • Rossella Iannotta
  • Costantino Romagnoli
  • Enrico Zecca
چکیده

BACKGROUND Continuous glucose monitoring using subcutaneous sensors has been validated in adults and children with diabetes, and was found to be useful in the management of glucose control. We aimed to assess feasibility and reliability of a new continuous glucose monitoring system (CGMS) in a population of preterm neonates using a Clarke error grid (CEG) specifically modified for preterm infants. METHODS Preterm infants were recruited within 24 h from delivery. A subcutaneous sensor connected to a CGMS was inserted and maintained for 6 days. Data collected from CGMS were compared with data obtained using a glucometer. Management of the infants followed standard protocols and was not influenced by CGMS readings. RESULTS Twenty patients (9 males) were included. Median (range) gestational age was 32 weeks (27-36) and median (range) birth weight was 1350 g (860-3360). Average CGMS recording time was 137 h, for a total of 449 paired glucose levels. CEG and modified CEG criteria for clinical significance were met. CONCLUSION CGMS is a safe and clinically adequate method to estimate glucose levels in preterm infants. As the glucose level can be evaluated in real time, this CGMS could be useful to reduce the number of heel sticks, to observe glycaemic trends and to promptly detect episodes of both hypo- and hyper-glycaemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data.

OBJECTIVE The objective of this study was to introduce continuous glucose-error grid analysis (CG-EGA) as a method of evaluating the accuracy of continuous glucose-monitoring sensors in terms of both accurate blood glucose (BG) values and accurate direction and rate of BG fluctuations and to illustrate the application of CG-EGA with data from the TheraSense Freestyle Navigator. RESEARCH DESIG...

متن کامل

The value of real-time continuous glucose monitoring in premature infants of diabetic mothers

To determine the feasibility of using a real-time continuous glucose monitoring system (RTGMS) in intensive care units, our study focus on preterm infants with diabetic mothers owing to their high risk of blood sugar abnormalities. Thirty preterm babies (M = 15 and F = 15; ≤ 36 week gestation age) were studied from within 72 hours of delivery. These babies were admitted to the newborn intensive...

متن کامل

Real-Time Continuous Glucose Monitoring Shows High Accuracy within 6 Hours after Sensor Calibration: A Prospective Study

Accurate and timely glucose monitoring is essential in intensive care units. Real-time continuous glucose monitoring system (CGMS) has been advocated for many years to improve glycemic management in critically ill patients. In order to determine the effect of calibration time on the accuracy of CGMS, real-time subcutaneous CGMS was used in 18 critically ill patients. CGMS sensor was calibrated ...

متن کامل

Continuous glucose monitoring accuracy results vary between assessment at home and assessment at the clinical research center.

BACKGROUND Continuous glucose monitoring system (CGMS) accuracy is of critical importance both in delivering therapeutic value and as a component of a closed-loop system. This study aims at assessing the differences between accuracy assessments of CGMS at home and at the clinical research center (CRC). METHODS Twelve patients with type 1 diabetes used the Dexcom® SEVEN® PLUS (DexCom, Inc.) CG...

متن کامل

Validation and feasibility of two Continuous Glucose Monitoring

Purpose: To validate two Continuous Glucose Monitoring systems (CGMs) against arterial AccuChek® point-of-care glucose measurements in critically ill patients. Methods: Two CGMs, Guardian RT® (GRT) and Freestyle Navigator® (FsN), were used for 5 days in mechanically ventilated patients with Multiple Organ Dysfunction syndrome. The measurements at T=0, T +10 min and T + 20 min were linked to T=0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Italian journal of pediatrics

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2016