Protocol Techniques for Testing Radiotherapy Accelerators
نویسندگان
چکیده
The nature of radiotherapy accelerators is briefly explained. It is argued that these complex safety-critical systems need a systematic basis for testing their software. The paper describes a novel application of protocol specification and testing methods to radiotherapy accelerators. An outline specification is given in LOTOS (Language Of Temporal Ordering Specification) of the accelerator control system. It is completely infeasible to use this directly for test generation. Instead, specification inputs are restricted using annotations in a Parameter Constraint Language. This is automatically translated into LOTOS and combined with the accelerator specification. It then becomes manageable to generate tests automatically of the actual accelerator to check that it agrees with its specification according to the relation ioconf (input-output conformance). Sample input annotations, their translation to LOTOS, and the resulting test cases are described.
منابع مشابه
Systematic Testing of Radiotherapy Accelerators
The nature of radiotherapy accelerators is briefly explained. It is argued that these complex safety-critical systems need a systematic basis for testing their software. The paper describes a novel application of protocol specification and testing methods to radiotherapy accelerators. It is explained that the accelerator control system is specified using LOTOS (Language Of Temporal Ordering Spe...
متن کاملFormally-Based Testing of Radiotherapy Accelerators
The paper presents the aims and research plan of the CONFORMED project (Conformance Of Radiological/Medical Devices). This three-year project will develop tools and techniques for modelling and testing radiotherapy equipment. Formal specifications in LOTOS (Language Of Temporal Ordering Specification) will be used to model accelerators formally and to derive tests rigorously based on these spec...
متن کاملبررسی وضعیت شتابدهنده خطی الکترون در درمان سرطان در ایران
Medical electronlinear accelerators are the most practical radiotherapy facilities in cancer treatment. About 52 percent of patients are treated by these radiotherapy systems during their treatment process. However, in developing countries there are not enough systems and recent studies reported the shortage of 5000 megavoltage radiotherapy accelerators all over the world. According to internat...
متن کاملPhoton Dosimetry Quality Audit of Radiotherapy Centers in Iran: SSDL's On-Site Visit Program During 2007-2017
Introduction: A dosimetric audit is a quality assurance process (QA) that allows the accuracy of dosimetric and geometric precision to accurately control the delivery of doses. They can be used to evaluate the accuracy of radiation delivery at different radiotherapy centers. Differences in prescriptive doses, depending on the severity of the differences, have potential conseque...
متن کاملA study on needed or unneeded ReDosimetry and Recomissioning of a linac with Add on MLC by Comparing Dosimetric Data
Introduction: Today different uses of multileaf collimators(MLC) in different techniques of radiotherapy are common. Due to the use of this facility it is possible to have maximum radiation dose to target volumes and minimum radiation dose to critical tissues surronding treatment volumes. But there are numerouse Linear accelerators in IRAN without MLC. Because of high price of...
متن کامل