Survey of aerosol delivery techniques to spontaneously breathing tracheostomized children.
نویسندگان
چکیده
BACKGROUND Therapeutic inhaled aerosols are often delivered to spontaneously breathing tracheostomized children. Although aerosol delivery can be affected by several factors, no recommendations for device/drug formulation choice are available. We hypothesized that practice modalities will vary among different institutions. METHODS The respiratory care departments in institutions in the United States that train pediatric pulmonologists were surveyed regarding their practices of delivering aerosols to spontaneously breathing tracheostomized children. Characteristics of the institution; use of metered-dose inhalers (MDIs), nebulizers, and dry powder inhalers; use of a resuscitation bag to aid aerosol delivery (assisted); types of medication used; and factors affecting choice of delivery method were recorded. RESULTS Of the invited institutions, 81% (38/47) participated, with 68% of them being freestanding children's hospitals. MDIs were used by 92% of the institutions surveyed, with similar use of unassisted (32%, with 83% of them using spacers), assisted (34%, with 100% of them using non-valved spacers), and both techniques (34%). Nebulizers were used by 97% of the institutions surveyed, with all using unassisted and 32% also using assisted technique. Tracheostomy aerosol mask was the most commonly used interface (89%). Assisted technique for either MDI or nebulizer was used by 68% of the institutions surveyed, with similar use of flow-inflating bag, self-inflating bag, and both devices. Types of inhaled medications utilized by surveyed institutions included aerosolized antibiotics (82%), corticosteroids (100%), short-acting β agonists (100%), combination therapy (32%), and mucolytics (84%). Dry powders were not used. Patient cooperation was the most frequent and single most important factor influencing the choice of delivery method. CONCLUSIONS A wide variation in practice of delivering aerosols to spontaneously breathing tracheostomized children was noted. In-vivo and in-vitro studies are needed to support clinical recommendations.
منابع مشابه
Nebulized albuterol delivery in a model of spontaneously breathing children with tracheostomy.
BACKGROUND Nebulized therapy is commonly used in spontaneously breathing tracheostomized patients, despite a lack of recommended devices and techniques. I compared albuterol dose delivered to a model of spontaneously breathing children with tracheostomy, using different nebulizers, tracheostomy tube sizes, inhalation techniques, and breathing patterns. METHODS A tracheostomy model was connect...
متن کاملPerformance Comparisons of Jet and Mesh Nebulizers Using Different Interfaces in Simulated Spontaneously Breathing Adults and Children.
BACKGROUND Different types of nebulizers and interfaces are used for the treatment of adults and children with pulmonary diseases. The purpose of this study was to determine the efficiency of a mesh nebulizer (MN) with a proprietary adapter and a jet nebulizer (JN) under different configurations in adult and pediatric models of spontaneous breathing. We hypothesize that delivery efficiency of J...
متن کاملThe Effect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Model with a Tracheostomy
Background: Evidence on aerosol delivery via tracheostomy is lacking. The purpose of this study was to evaluate the effect of aerosol device and administration technique on drug delivery in a simulated spontaneously breathing pediatric model with tracheostomy. Methods: Delivery efficiencies during spontaneous breathing with assisted and unassisted administration techniques were compared using t...
متن کاملAerosol delivery during mechanical ventilation: from basic techniques to new devices.
Pressurized metered-dose inhalers (pMDIs) and nebulizers are routinely employed for aerosol delivery in mechanically ventilated patients. A significant proportion of the aerosol deposits in the ventilator circuit and artificial airway, thereby reducing the inhaled drug mass. Factors influencing aerosol delivery during mechanical ventilation differ from those in spontaneously breathing patients....
متن کاملNebulized drug delivery in patients breathing spontaneously through an artificial airway.
During the past 25 years, incremental gains in knowledge about aerosol delivery to mechanically ventilated patients had a major impact on patient care in this setting. The complex array of factors influencing aerosol delivery during mechanical ventilation made it difficult to elucidate the contribution of individual parameters to optimal aerosol delivery. Over the ensuing years, bench models ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 57 8 شماره
صفحات -
تاریخ انتشار 2012