The Modulated - Input Modulated - Output
نویسندگان
چکیده
In this paper we discuss why message acknowledgements are an appropriate engineering approach to meet system functionality. The data replication problem in database systems is our motivation. We introduce a new queueing theoretic model, the MIMO model, that incorporates burstiness in the sending side and busy periods in the receiving side. Based on simulation results derived from this model, we show that the buuer requirements from M/M/1/N queues are too optimistic.
منابع مشابه
Effect of Pulse-Modulated GSM-900 MHz Electromagnetic Field on the Electrochemotherapy Efficacy of 4T-1 Cells
Introduction: Electrochemotherapy (ECT) is a cancer treatment modality to permeabilize cell membrane facilitating the non-permeant molecules to gain access to the cytosol of cells. Nevertheless, environmental electromagnetic fields (EMFs) may disturb the efficiency of ECT. The present study aimed to investigate the effect of EMFs 900 MHz pulse-modulated by 217 Hz extremely low-frequency fields ...
متن کاملThe Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry
Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...
متن کاملTheory and Implementation of RF-Input Outphasing Power Amplification
Conventional outphasing power amplifier systems require both an RF carrier input and a separate baseband input to synthesize a modulated RF output. This work presents an RF-input / RF-output outphasing power amplifier that directly amplifies a modulated RF input, eliminating the need for multiple costly IQ modulators and baseband signal component separation as in previous outphasing systems. An...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملEvaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...
متن کامل