Could We Characterize Fine Structures in Human Brain Using High-resolution Magnitude and Phase image at 7 Tesla In Vivo?
نویسندگان
چکیده
[Introduction] The high-field scanner (≥ 7T) has potential advantages of high SNR, CNR, and spatial-resolution in human brain imaging. MR magnitude and phase image at 7T shown the unprecedented high T2*-weighted contrast in deoxygenated vessels [1, 2] and iron-deposit region such as basal ganglia or deep brain nucleus [3]. While the magnitude signal is determined by T2* relaxation time, proton-density, and water contents, the phase is affected mainly by the local field inhomogeneity [4]. These two different characteristics can be utilized to characterize the signal source of brain structures, particularly the fine hair-like structures in human brain such as vessels or neuronal fibers. In this study, the high-resolution brain anatomy images were obtained in the cortex through deep brain using the developed reconstruction algorithm at 7T equipped with multi-channel RF coil [5]. [Methods] All scans were performed on Trio7T scanner (Siemens Medical Solutions, Erlangen, Germany) with 9channel RF coil (1 volume transceiver + 8 surface receivers). Three normal volunteers consented to the study approved by the IRB of the university. Dual-echo 2D GRE sequence was used to get the T2*-weighted MR images [5]. As a comparison study, the typical True-FISP image was acquired to get the heavily water-weighted image in cerebral-spinal-fluid for one case. For the vessel simulation, the infinite-long cylindrical model [6] was used to calculate the inhomogeneous field in the neighboring space at 7T; susceptibility difference between blood and tissue 1.0×10, hematocrit concentration 0.4, fractional oxygen saturation of hemoglobin 0.55 during rest period, and cylinder radius 150 μm (Fig. 1A). The direction of cylinder was changed with two rotation angles (α & β for xand y-axis). The phase was converted from the calculated inhomogeneity field by , where γ is gyromagnetic ratio and TE is echo time 20 ms. The spin density assumed to be same in tissue and blood for the simplicity. The magnetization at the center of vessel was integrated over 2 mmthick slice in axial, coronal, and sagittal image in complex domain (Figs. 1B – D) with different orientation of cylinder. The visual cortex, basal ganglia, and pons were selected for the detail analysis of anatomy using reconstructed magnitude and phase images. Particularly, the fine hair-like structures were focused to understand the anatomical source of intensity based on our simulation. [Results and Conclusions] In the vessels, the results of simulation and MR images were well correlated. That is, the phase in axial view was always negative under paramagnetic susceptibility condition ( ) (Figs. 1B & 2B); positive with diamagnetic condition ( ). In sagittal (coronal) view, the polarity of phase changes from negative to positive when the cylinder is in parallel to orthogonal to field (Figs. 1C & D and 2D & F); there are the transient points where the phase becomes zero (white-trace in Fig. 1C and magenta-arrowheads or -brackets in Figs. 2D & F). Some micro-structures showed the different characteristics from the deoxygenated vessels filled with paramagnetic susceptibility blood (Fig. 3). The hyperintense (nullified) vessel-like fine structure in magnitude (phase) image at the parietotemporal visual cortex was proved to be the CSF around artery by comparison of magnitude, phase, and True-FISP images (see yellow-arrowheads in Figs. 3A C). In the midbrain, dark lines are supposed to be vessels in magnitude image, and the corresponding phase values are well matched with simulation (i.e., horizontal – bright & vertical – dark) (red-arrowheads in Figs. 3D & E), but the white lines in magnitude didn’t show the consistent phase values (yellowarrowheads). Another interesting thing was the micro-stripe structures in sagittal image (Figs. 3F I). Based on simulation results, the horizontal lines are vessels (red-arrowheads in Figs. 3F & G) and the vertical lines are not the deoxygenated vessels, but possibly the corticospinal cord (yellow-arrowheads in Figs. 3H & I). In conclusion, the fine structures in human brain can be characterized using high-resolution magnitude and phase images acquired at high-field magnet 7T. [Reference] 1. Hammond et al. Neuroimage, 2007. 2. Duyn et al., PNSA, 2007. 3. Abduljalil et al., JMRI, 2003. 4. Haccke et al., JMRI, 2007. 5. Moon et al., ISMRM, 2009, submitted. 6. Ogawa et al., PNAS, 1990. Acknowledgements] We thank Dr. Z.H. Cho for the support of a 7T multi-channel head RF coil. Fig. 1 (A) Cylindrical model for the bloodvessel simulation, and the phase distribution in (B) axial (x-z plane), (C) sagittal (y-z plane), and (D) coronal view (x-y plane). Whitedashed traces represent the direction of vessels with zero phase values in C and D. 'H' – horizontally, and 'V' – vertically oriented vessel. The voxel phase had the maximum negative polarity for the cylinder lying in the magnetic field direction (asterisk in B), but it didn’t change over a relatively broad range of tilting angle toward field (e.g., 0° ~65°) (gray-trace in B). In sagittal view, the voxel phase is negative with a parallel direction of cylinder to field, while positive with the orthogonal direction of cylinder to magnet field . At these zero phase points in C, the angle between the axis of cylinder and magnet field ranges from to in this simulation.
منابع مشابه
Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملHigh-field MRI of brain cortical substructure based on signal phase.
The ability to detect brain anatomy and pathophysiology with MRI is limited by the contrast-to-noise ratio (CNR), which depends on the contrast mechanism used and the spatial resolution. In this work, we show that in MRI of the human brain, large improvements in contrast to noise in high-resolution images are possible by exploiting the MRI signal phase at high magnetic field strength. Using gra...
متن کاملHigh-resolution in vivo MR imaging of the human spinal cord at 7 Tesla
[Introduction] MR imaging of spinal cord is an important component of diagnostic work-up in some diseases such as multiple sclerosis (MS). In MS, the spinal cord is frequently involved and often in combination with lesions in the brain. In some MS cases, lesions have been found to involve only the spinal cord, particularly in the cervical spinal cord. Compared to brain imaging, spinal imaging i...
متن کاملTowards an in-vivo and post-mortem characterization of chronic multiple sclerosis lesions using susceptibility related mechanisms of contrast at ultra-high field MRI with R2* and phase images
Introduction: R2 and phase images derived from high-resolution 7 Tesla magnetic susceptibility-weighted MRI provide a rich contrast in healthy and diseased human brain. Yet, the sources that contribute to this contrast are not fully understood. Previous studies suggest that iron and myelin brain content may each contribute to R2 and phase in a different manner [1]. In this study, we used multip...