Lack of Teratological Effects in Rats Exposed to 20 or 60 kHz Magnetic Fields

نویسندگان

  • Izumi Nishimura
  • Atsushi Oshima
  • Kazumoto Shibuya
  • Tadashi Negishi
چکیده

BACKGROUND A risk assessment of magnetic field (MF) exposure conducted by the World Health Organization indicated the need for biological studies on primary hazard identification and quantitative risk evaluation of intermediate frequency (300 Hz-100 kHz) MFs. Because induction heating cookers generate such MFs for cooking, reproductive and developmental effects are a concern due to the close proximity of the fields' source to a cook's abdomen. METHODS Pregnant Crl:CD(SD) rats (25/group) were exposed to a 20 kHz, 0.2 mT(rms) or 60 kHz, 0.1 mT(rms) sinusoidal MF or sham-exposed for 22 hr/day during organogenesis, and their fetuses were examined for malformations on gestation day 20. All teratological evaluations were conducted in a blind fashion, and experiments were duplicated for each frequency to confirm consistency of experimental outcomes. RESULTS No exposure-related changes were found in clinical signs, gross pathology, or number of implantation losses. The number of live fetuses and low-body-weight fetuses as well as the incidence of external, visceral, and skeletal malformations in the fetuses did not indicate significant differences between MF-exposed and sham-exposed groups. Although some fetuses showed isolated changes in sex ratio and skeletal variation and ossification, such changes were neither reproduced in duplicate experiments nor were they common to specific field frequencies. CONCLUSIONS Exposure of rats to MFs during organogenesis did not show significant reproducible teratogenicity under experimental conditions. Present findings do not support the hypothesis that intermediate frequency MF exposure after implantation carries a significant risk for developing mammalian fetuses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute and subchronic toxicity of 20  kHz and 60  kHz magnetic fields in rats

Despite increasing use of intermediate frequency (IF) magnetic fields (MFs) in occupational and domestic settings, scientific evidence necessary for health risk assessments of IF MF is insufficient. Male and female Crl:CD(SD) rats (12 per sex per group) were exposed to 20 kHz, 0.20 mT(root mean square, rms) or 60 kHz, 0.10 mT(rms) sinusoidal MFs for 22 h day(-1) for 14 days (acute) or 13 weeks ...

متن کامل

The effect of 17 days exposure to static magnetic fields on the hypothalamic-pituitary-gonadal axis in the male rat

Power stations produce a range of magnetic fields more than 20 mT which are harmful to those working or living around them. Several investigators have reported an increased health risk due to exposure to electric and magnetic fields (EMF) at 50 and 60 Hz. Several studies have been reported especially with increased tumor incidence, effects on reproduction and development, and neural and behavio...

متن کامل

The effect of 17 days exposure to static magnetic fields on the hypothalamic-pituitary-gonadal axis in the male rat

Power stations produce a range of magnetic fields more than 20 mT which are harmful to those working or living around them. Several investigators have reported an increased health risk due to exposure to electric and magnetic fields (EMF) at 50 and 60 Hz. Several studies have been reported especially with increased tumor incidence, effects on reproduction and development, and neural and behavio...

متن کامل

P-104: Effects of Prenatal Exposure to Electromagnetic Fields on Fertility of F1 Generation in In Vitro

Background: Electromagnetic fields interact with human tissues and may have adverse effects on fertility and reproduction. During the last decades there has been a growing concern on the effects of electromagnetic radiations on biological systems in general. Radiation risks from electromagnetic fields generated by processes such as reduced fertility and a significant decrease in implantation ra...

متن کامل

Comparison of cardiac and 60 Hz magnetically induced electric fields measured in anesthetized rats.

Extremely low frequency magnetic fields interact with an animal by inducing internal electric fields, which are in addition to the normal endogenous fields present in living animals. Male rats weighing about 560 g each were anesthetized with ketamine and xylazine. Small incisions were made in the ventral body wall at the chest and upper abdomen to position a miniature probe for measuring intern...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 92  شماره 

صفحات  -

تاریخ انتشار 2011