Experience with the Mentor Contour Profile Becker-35 expandable implants in reconstructive breast surgery.

نویسندگان

  • Frank Hsieh
  • Amit Shah
  • Charles M Malata
چکیده

INTRODUCTION Round expander-implants (Beckers 25 and 50) and anatomical expander-prostheses filled with firm cohesive gel (McGhan Style 150) are established choices for single-stage expander breast reconstruction. Because of their drawbacks we selectively adopted the anatomical Becker-35 expander-implant filled with soft cohesive gel from January 2005. PATIENTS AND METHODS All patients undergoing reconstructive breast surgery using the Contour Profile Becker-35 expandable implant over a two-year period were retrospectively reviewed with respect to indication, implant sizes, inflation details, complications and outcomes. RESULTS 36 patients, mean age 48.9 years (r=14-69), received 39 anatomical Becker-35 expanders (three bilaterally). Three quarters of these implants (29) were used for immediate breast reconstruction while the remainder were equally divided between delayed postmastectomy reconstruction (5) and correction of congenital breast asymmetry (5). Half of the patients had simultaneous latissimus dorsi myocutaneous flap coverage of the implants. The median numbers of inflations and deflations needed to achieve the target expansion size and shape were 3 (r=0-7) and 0 (r=0-4), respectively. The mean time from expander insertion to completion of reconstruction was 4.6 months (r=0-13 months). Four patients required surgical intervention for haematoma, implant infection, severe capsular contracture, and palpable rippling. Additionally there were three injection port adjustments, giving a 20% overall revisional surgery rate (8/39 breasts) after a median follow-up of 20 months (r=6-38 months). Four implants (10%) developed significant but asymptomatic rippling. The significant capsular contracture rate was 21% (8/39 breasts), which was related to chest wall radiotherapy. CONCLUSION In this short-term study, the Becker-35 expander was successfully used for single-stage prosthetic breast reconstruction with an incidence of early complications comparable to alternative prostheses. Although it has expanded the range of implants available to the breast surgeon, its exact role in reconstructive breast surgery has yet to be established.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early experience with an anatomical soft cohesive silicone gel prosthesis in cosmetic and reconstructive breast implant surgery.

Recently, an anatomic breast implant filled with soft cohesive silicone gel was introduced by Mentor Medical Systems onto the European market. This study reports the early experience of a single surgeon with this implant. All patients who received a Contour Profile Gel (CPG) implant from March 2001 to October 2002 were studied. Patient satisfaction with breast shape and consistency was assessed...

متن کامل

Mentor Contour Profile Gel implants: clinical outcomes at 6 years.

BACKGROUND MemoryShape (Contour Profile Gel) is a textured contoured implant filled with a cohesive silicone gel intended for use in aesthetic and reconstructive breast surgery. The 6-year summary of the clinical outcomes and satisfaction rates for this device from a 10-year, prospective, open-label, multicenter clinical trial is presented. METHODS According to 2006 guidelines set forth by th...

متن کامل

Reply: Comparison of Allergan, Mentor, and Sientra Contoured Cohesive Gel Breast Implants: A Single Surgeon's 10-Year Experience.

www.PRSJournal.com 958 Reply: Comparison of Allergan, Mentor, and Sientra Contoured Cohesive Gel Breast Implants: A Single Surgeon’s 10-Year Experience: Correction I the September 2016 letter by Afrooz and Davidson entitled “Reply: Comparison of Allergan, Mentor, and Sientra Contoured Cohesive Gel Breast Implants: A Single Surgeon’s 10-Year Experience” (Plast Reconstr Surg. 2016;138:549e–550e),...

متن کامل

Comparison of breast implant deflation for mentor anterior and posterior valve designs in aesthetic and reconstructive patients.

BACKGROUND Saline breast implant rupture remains problematic after implantation. Company reports and previous studies implicate the valve as a common site of implant failure. This study evaluates the rupture rate of the Mentor posterior valve compared with the anterior valve in breast augmentation and reconstruction. METHODS This is a retrospective analysis of consecutive breast implantations...

متن کامل

Anaplastic Large Cell Lymphoma Associated with Breast Implant: A Case Report

Primary breast lymphoma represents less than 1% of all primary breast malignancies and most primary breast lymphomas are of B-Cell origin. The association of anaplastic lymphoma kinase (ALK) negative anaplastic large cell lymphoma (ALCL), a very rare form of primary breast lymphoma, with silicone-filled breast implants has been suggested and several case reports supported this proposal, especia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of plastic, reconstructive & aesthetic surgery : JPRAS

دوره 63 7  شماره 

صفحات  -

تاریخ انتشار 2010