Measurement of Central Venous Pressure Using Ultrasound in Emergency Department

نویسندگان

  • Ahmad Abbasian
  • Hamideh Feiz Disfani
  • Mohammad Afzalimoghaddam
  • Mohammad Taghi Talebian
  • Babak Masoumi
  • Mohammad Nasr-Esfahani
چکیده

BACKGROUND In order to assessment of intravascular fluid measurement of central venous pressure (CVP) is used via central venous catheterization (CVC). This procedure is highly invasive and may cause serious complications such as pneumothorax, infection, hematoma and etc. It is so valuable procedure if we can uses a less invasive or noninvasive procedure to assess patients intravascular fluid in critical positions. OBJECTIVES In this study, the ultrasound was used to measure the central venous pressure (CVP). PATIENTS AND METHODS In this study, patients with Central venous catheterization were selected using simple random sampling. The largest diameter of longitudinal, transverse views and the cross-section of inferior vena cava (IVC) and internal jugular vein (IJV) were measured using the ultrasound in the bedside of the patients. Central venous pressure was measured using routine methods. Correlations between variables were analyzed using SPSS and linear regression. RESULTS Twenty patients with the mean age of 60.3 were studied. The main reason for cardiac catheterization was shock. There are no relationship between anterior posterior diameter of inferior vena cava and CVP of patients (P = 0.257). The longest diameter of IVC in ultrasonographic transverse view had significant association with CVP of patients (P = 0.045) but in patients with BMI > 25 it was not significant. Cross section of internal jugular vein had significant association with CVP of patients (P = 0.003). Longitudinal diameter of internal jugular vein had no significant association with CVP of patients (P = 0.052), but transverse diameter of internal jugular generally had significant association with CVP of patients (P = 0.003). Cross section of internal jugular had significant association with CVP (P = 0.001). CONCLUSIONS Noninvasive assessment of the patient hydration condition using the ultrasound is a simple and practicable measure in emergency. With regard to the considerations, it is possible to estimate CVP via diameter measurement and cross-section of the central veins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

An Evaluation of Complications in Ultrasound-Guided Central Venous Catheter Insertion in the Emergency Department

OBJECTIVES In emergency departments, emergency physicians frequently have to perform central venous access. In cases where peripheral venous access is not possible, central venous access is required for dialysis, fulfillment of urgent fluid need, or central venous pressure measurement. This study was carried out to evaluate the emergence of complications in the process of and in the 15 days fol...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

بررسی تأثیر استفاده از چک لیست ثبت اقدامات بر عملکرد پرستاران بخش مراقبت های ویژه در اندازه‌گیری فشار ورید مرکزی

  Background & Aim: The central venous pressure measurement is a common and important care provided by nurses in intensive units. The measurement should be according to the pre-defined standards. The purpose of this study was to evaluate the effect of using a checklist in measuring central venous pressure by nurses .   Methods & Materials: This was a nonequivalent group design on 70 nurses w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015