The prestretching effect on the force decay of orthodontic elastic chain.

نویسندگان

  • Adelson Mota de Aguiar
  • Arilton Mota de Aguiar
  • Júlio de Araújo Gurgel
  • Celia Regina Maio Pinzan Vercelino
  • Etevaldo Matos Maia Filho
  • Matheus Coelho Bandeca
  • Rudys Rodolfo de Jesus Tavarez
چکیده

This in vitro study evaluated the Influence of prestretching, in the force decay of orthodontic elastic chains, at three time intervals: 2, 7 and 30 days with the brands Morelli, Orthometric and American Orthodontics. In the experimental group, prestretching was performed, stretching the elastics to increase them by 50% of their original length three times in a quick and sequential mode. All of the elastic chains were kept stretched and stored in artificial saliva at 37°C until the time of force measurement. For comparisons between the control and experimental groups, the Mann-Whitney test was used. For comparisons between time points and brands, the Kruskal-Wallis test was used, and for multiple comparisons, Miller's post-hoc test was used. The results showed statistically significant differences among the different commercial brands tested at the initial time point. The mean force at the initial time point ranged from 2.57 to 3.17 N. By day 2, the force values were between 0.97 and 1.49 N; by day 7, the values were 0.56 and 0.94 N. By day 30, the force values ranged between 0.27 and 0.66 N. We concluded that performing and duration of prestretching and the brand all Influenced the force decay of orthodontic elastic chains. Time had a greater Influence on the decay of the elastics than brand or prestretching.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of preloading on stress relaxation of orthodontic elastic polymers.

The main objective of the investigation was the determination of whether prestretching would decrease the rapid force loss of the elastic polymers. The results indicated that Alastik CK chains showed a significant decrease in force loss whereas the C2 chains were unaffected. Since overextending the chain to compensate for force loss during clinical placement could result in capillary bed ischem...

متن کامل

Effects of Orthokin, Sensikin and Persica mouth rinses on the force degradation of elastic chains and NiTi coil springs

Background. Elastomeric chains and NiTi coil springs are two major traction aids in orthodontic tooth movements. Force degradation occurs over time in both groups, with higher percentages in elastic chains. The effects of environmental factors and some mouth rinses on this force decay have been previously studied. No study has been performed to evaluate the effect of current popular mouth rinse...

متن کامل

Evaluation of the effects of three different mouthwashes on the force decay of orthodontic chains

BACKGROUND Elastomeric chains are commonly used in orthodontics. Force decay in these materials poses clinical problems. The aim of this study was to evaluate the effects of three different mouthwashes on the force decay of orthodontic chains. MATERIALS AND METHODS In this experimental study, elastomeric chains with two different configurations were divided into eight groups (two control and ...

متن کامل

The effect of different environmental factors on force degradation of three common systems of orthodontic space closure

BACKGROUND Different environmental conditions, such as high temperature or exposure to some chemical agents, may affect the force decay of different methods of space closure during orthodontic treatment. The aim of this in vitro study was to evaluate the force decay pattern in the presence of tea as a popular drink in some parts of the world and two mouthwashes that are usually prescribed by th...

متن کامل

بررسی نقش لیزر هلیوم- نئون در کاهش درد ناشی از ارتودنسی: کارازمائی بالینی

Background and purpose: Low level lasers have been used in dentistry to stimulate orthodontic tooth movement and to inhibit the pain during tooth movements. Contradictory findings exist on this issue, therefore, this study evaluated the effect of laser therapy on pain during orthodontic tooth movement. Material and methods: In this clinical trial, 17 patients with extracted upper first premola...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2014