Application of quantitative real-time PCR with dual-labeled hydrolysis probes to microbial water quality monitoring.
نویسندگان
چکیده
Issues of water quality are a global problem with potentially devastating results in communities if microbial levels are not monitored and controlled effectively.This is especially true with the potential threat of bioterrorist contamination of water supplies.This study presents a method for quantifying microbial water pathogens by 5' nuclease real-time polymerase chain reaction analysis, thus decreasing the assay time (under 2 h for completion of thermal cycling and analysis) and increasing the sensitivity and precision of detection as compared with traditionally used assays. We have quantified Escherichia coli, toxigenic E. coli O157:H7, the microcystin-producing cyanobacterium Microcystis aeruginosa, and the protozoan parasite Giardia lamblia. Our measurements have detected as few as three cells per sample for the bacterial targets and one cell per sample for G. lamblia. The quantification of total E. coli and microcystin-producing cyanobacteria has been extended to the analysis of environmental samples.
منابع مشابه
Evaluation of dual-labeled fluorescent DNA probe purity versus performance in real-time PCR.
Real-time PCR technology using dual-labeled fluorescent oligonucleotide probes allows for sensitive, specific, and quantitative determination of mRNA or DNA targets. Historically, dual-labeled probes have been the most expensive reagent in real-time PCR because of the postsynthesis high-performance liquid chromatography (HPLC) and/or gel purification steps required due to limitations in traditi...
متن کاملProbeLibrary: A new method for faster design and execution of quantitative real-time PCR
ProbeLibrary, a fast, specific and flexible format for quantitative real-time PCR, is described. The ProbeLibrary concept is based on the fact that just 90 short probes provide transcriptome-wide coverage in most organisms. These short probes are highly specific and possess the high melting temperature (Tm) required for real-time PCR owing to the incorporation of locked nucleic acid (LNA). The ...
متن کاملPCR bias in ecological analysis: a case study for quantitative Taq nuclease assays in analyses of microbial communities.
Succession of ecotypes, physiologically diverse strains with negligible rRNA sequence divergence, may explain the dominance of small, red-pigmented (phycoerythrin-rich) cyanobacteria in the autotrophic picoplankton of deep lakes (C. Postius and A. Ernst, Arch. Microbiol. 172:69-75, 1999). In order to test this hypothesis, it is necessary to determine the abundance of specific ecotypes or genoty...
متن کاملBasic principles of real-time quantitative PCR.
Real-time quantitative PCR allows the sensitive, specific and reproducible quantitation of nucleic acids. Since its introduction, real-time quantitative PCR has revolutionized the field of molecular diagnostics and the technique is being used in a rapidly expanding number of applications. This exciting technology has enabled the shift of molecular diagnostics toward a high-throughput, automated...
متن کاملDroplet digital PCR for simultaneous quantification of general and human-associated fecal indicators for water quality assessment.
Despite wide application to beach water monitoring and microbial source identification, results produced by quantitative PCR (qPCR) methods are subject to bias introduced by reliance on quantitative standards. Digital PCR technology provides direct, standards-free quantification and may potentially alleviate or greatly reduce other qPCR limitations such as difficulty in multiplexing and suscept...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomolecular techniques : JBT
دوره 13 4 شماره
صفحات -
تاریخ انتشار 2002