Development of a low background liquid scintillation counter for a shallow underground laboratory.

نویسندگان

  • J L Erchinger
  • C E Aalseth
  • B E Bernacki
  • M Douglas
  • E S Fuller
  • M E Keillor
  • S M Morley
  • C A Mullen
  • J L Orrell
  • M E Panisko
  • G A Warren
  • R O Williams
  • M E Wright
چکیده

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., β and α) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35m-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation counter's shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Strontium-90 in the Persian Gulf Fish by Extraction Chromatography with Sr-resin and Liquid Scintillation Counter

Background: Despite its beneficial effects on human life, the nuclear industry has its own risks. Strontium 90 (90Sr) is one of the most dangerous radionuclides produced by the uranium 235 fission, and replaces the bone calcium in the human body, which causes cancer. Ensuring the safety of nuclear facilities to protect employees, people and the environment is among the main goals of nuclear saf...

متن کامل

Low Background Liquid Scintillation in Borexino

After a short introduction to solar neutrino physics, this paper describes the design concept and expected performance of the Borexino underground detector at Gran Sasso. Low background results from the Counting Test Facility, the rst phase of the Borexino project, are summarized.

متن کامل

A performance comparison of nine selected liquid scintillation cocktails.

Sample load capacity, sample compatibility, influence of sample load on (3)H/(14)C counting efficiency, background count rate, figure of merit, quench resistance, and sample stability for nine selected, commercially available, liquid scintillation cocktails are presented in this study. The cocktails tested are Ecoscint A, Insta-Gel Plus, OptiPhase Hisafe 3, OptiPhase Trisafe, Ready Gel, SafeSci...

متن کامل

Automation of a Beckman liquid scintillation counter for data capture and data-base management

A software package for the automation of a Beckman LS9000 liquid scintillation counter is presented. The package provides effective on-line data capture (with a Perkin Elmer 3230 32-bit minicomputer), database management, audit trail and archiving facilities. Key features of the package are rapid andJlexible data entry, background subtraction, half-life correction, ability to queue several samp...

متن کامل

First measurement of low intensity fast neutron background from rock at the Boulby Underground Laboratory

A technique to measure low intensity fast neutron flux has been developed. The design, calibrations, procedure for data analysis and interpretation of the results are discussed in detail. The technique has been applied to measure the neutron background from rock at the Boulby Underground Laboratory, a site used for dark matter and other experiments, requiring shielding from cosmic ray muons. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 105  شماره 

صفحات  -

تاریخ انتشار 2015