False-positive buprenorphine by CEDIA in patients prescribed amisulpride or sulpiride.

نویسندگان

  • M A Birch
  • L Couchman
  • S Pietromartire
  • T Karna
  • C Paton
  • R McAllister
  • A Marsh
  • R J Flanagan
چکیده

Buprenorphine is a potent partial opioid agonist that is analyzed in urine to (i) monitor adherence to maintenance or detoxification therapy and (ii) detect illicit use. Buprenorphine analysis is commonly conducted on urine by immunoassay, but is subject to cross-reactivity from other drugs/drug metabolites, including morphine, codeine and dihydrocodeine. This study reports false-positive buprenorphine analysis [Thermo Fisher Scientific cloned enzyme donor immunoassay (CEDIA)] in patients who denied unauthorized buprenorphine use prior to sampling, but who had been prescribed amisulpride. In two cases, confirmatory analysis by liquid chromatography-tandem mass spectrometry was negative (<0.5 µg/L) for buprenorphine and metabolites and positive for amisulpride. Although the cross-reactivity of amisulpride and sulpiride in the CEDIA buprenorphine assay is low (estimated at 0.003 and 0.002%, respectively), it remains a significant consideration given the likely high concentrations of these compounds in urine relative to the low cutoff of the buprenorphine assay. Neither amisulpride nor sulpiride was listed as potential sources of interference on the CEDIA data sheet when this work was performed. These findings highlight the importance of confirming immunoassay-positive buprenorphine results using a more selective analytical technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of buprenorphine CEDIA assay versus GC-MS and ELISA using urine samples from patients in substitution treatment.

As buprenorphine becomes more clinically used in heroin substitution treatment, there is an increasing need for methods suitable for high-volume screening. In this study, a new immunochemical test based on CEDIA technology was evaluated for the use in clinical urine drug testing. The method was compared with an existing ELISA method and a gas chromatography-mass spectrometry (GC-MS) method on u...

متن کامل

Cross-reactivity of the CEDIA buprenorphine assay in drugs-of-abuse screening: influence of dose and metabolites of opioids

PURPOSE The cloned enzyme donor immunoassay (CEDIA) for buprenorphine is applied for both urine drugs-of-abuse screening and compliance monitoring. Sensitivity, specificity, and optimal cutoff of this assay have differed between studies. This may indicate that cross-reactivity has to be taken into account during assay evaluation. We therefore investigated the performance of the CEDIA buprenorph...

متن کامل

Detecting Potential Adverse Reactions of Sulpiride in Schizophrenic Patients by Prescription Sequence Symmetry Analysis

PURPOSE Previous studies have demonstrated sulpiride to be significantly more effective than haloperidol, risperidone and olanzapine in schizophrenic treatment; however, only limited information is available on the potential risks associated with sulpiride treatment. This study attempts to provide information on the potential risks of sulpiride treatment of schizophrenia, especially with regard...

متن کامل

Buprenorphine detection in urine using liquid chromatography-high-resolution mass spectrometry: comparison with cloned enzyme donor immunoassay (ThermoFisher) and homogeneous enzyme immunoassay (immunalysis).

A sensitive liquid chromatographic-high-resolution mass spectrometric (LC-HR-MS) assay for buprenorphine and its urinary metabolites has been developed that requires minimal sample preparation. The results obtained have been compared with those given by (i) cloned enzyme donor immunoassay (CEDIA) and (ii) homogeneous enzyme immunoassay (HEIA) in the analysis of patient urines submitted for bupr...

متن کامل

Urinary buprenorphine concentrations in patients treated with suboxone as determined by liquid chromatography-mass spectrometry and CEDIA immunoassay.

We report on the utility of urine total buprenorphine, total norbuprenorphine, and creatinine concentrations in patients treated with Suboxone (a formulation containing buprenorphine and naloxone), used increasingly for the maintenance or detoxification of patients dependent on opiates such as heroin or oxycodone. Patients received 8-24 mg/day buprenorphine. Two-hundred sixteen urine samples fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2013