Characterization of the inflammatory response to four commercial bone graft substitutes using a murine biocompatibility model
نویسندگان
چکیده
Bone grafting is utilized in nearly all orthopedic subspecialties and in most anatomic regions. Bone graft substitutes have the potential to offer similar efficacy as autogenous grafts without the morbidity of harvest. Several studies have noted the efficacy of new-generation bone substitute products, but few studies have evaluated their safety. This study characterizes and quantifies the inflammatory reaction to four different commercially available bone graft substitutes, which were examined using the in vivo murine air pouch biocompatibility model. One coralline hydroxyapatite product was chosen as an example of a purely osteoconductive material. Three demineralized bone matrix products were chosen to represent products that are both osteoconductive and osteoinductive. Samples were implanted in a murine air pouch and harvested after 14 days in situ. Pouch fluid was extracted, mRNA isolated, and reverse transcription polymerase chain reactions carried out to detect interleukin-1 gene expression as a marker for inflammation. In addition, multiple histological characteristics were examined to quantify cellular responses to the implanted materials. All bone graft substitutes induced a significant inflammatory response compared with negative controls. Histology and polymerase chain reaction data indicated that the level of inflammatory reaction was elevated in materials with a higher demineralized bone matrix to carrier proportion. The hydroxyapatite product generated a low inflammatory reaction. In conclusion, this study used an in vivo model of biocompatibility to demonstrate that a significant inflammatory reaction occurs when using implanted bone graft substitutes. When choosing a bone grafting method, surgeons should consider both the efficacy and safety of methods and materials used. Further studies are necessary to determine the ideal bone graft material to maximize efficacy while minimizing morbidity.
منابع مشابه
Chemical Preparation of Beta Calcium Sulfate Hemihydrate Granules with a Special Particle Size as Bone Graft Material
Introduction: Beta calcium sulfate hemihydrate (BCSH), which is commonly known as “Gypsum plaster” has long been used as bone graft material because of its excellent biocompatibility and the ability for bone regeneration. Several methods have been used for the preparation of BCSH, including heat treatment of calcium sulfate dihydrate with water, application of inorganic acids or condensed inorg...
متن کاملIn vivo analysis of biocompatibility and vascularization of the synthetic bone grafting substitute NanoBone.
One of the major challenges in the application of bone substitutes is adequate vascularization and biocompatibility of the implant. Thus, the temporal course of neovascularization and the microvascular inflammatory response of implants of NanoBone (fully synthetic nanocrystalline bone grafting material) were studied in vivo by using the mouse dorsal skinfold chamber model. Angiogenesis, microhe...
متن کاملBiocompatibility Issues with Modern Implants in Bone - A Review for Clinical Orthopedics
Skeletal defects may result from traumatic, infectious, congenital or neoplastic processes and are considered to be a challenge for reconstructive surgery. Although the autologous bone graft is still the "gold standard", there is continuing demand for bone substitutes because of associated disadvantages, such as limited supply and potential donor side morbidity [1]. This is not only true for in...
متن کاملTwo Composite Bone Graft Substitutes for Maxillary Sinus Floor Augmentation: Histological, Histomorphometric, and Radiographic Analyses.
OBJECTIVE To histologically, histomorphometrically, and radiographically compare clinical performance of 2 composite bone graft substitutes for maxillary sinus floor augmentation (MSFA). MATERIALS AND METHODS Partially or totally edentulous patients requiring MSFA underwent grafting procedures using a 2:1 mixture of biphasic calcium sulfate (CS) and deproteinized bovine bone (group CB) or bip...
متن کاملBSA nanoparticles loaded with IONPs for biomedical applications: fabrication optimization, physicochemical characterization and biocompatibility evaluation
Objective(s): Cancer diagnosis in its early stages of progress, can enhance the efficiency of treatment utilizing conventional therapy methods. Non-biocompatibility of iron oxide nanoparticles (IONPs) has made a big challenge against their usage as a contrast agent. Efficient coverage by biomolecules such as albumin can be a solution to overcome this problem. Herein, albumin-coated IONPs were p...
متن کامل