Wear of poly (methyl methacrylate) against a metallic surface in dry conditions

نویسندگان

  • Jean Geringer
  • Bernard Forest
  • Pierre Combrade
چکیده

Wear of Poly (Methyl MethAcrylate), PMMA, against a metallic surface, AISI 316L stainless steel, SS, has been investigated in dry conditions. These materials have been used to simulate the degradation of the contact, femoral stem-bone cement in the field of hip prosthesis. First of all, no significant wear was observed on the 316L SS. PMMA wear has been quantified: the energy wear coefficient, slope of the line, and wear volume according to the cumulated dissipated energy, don’t depend on the normal load, FN. This energy analysis allows predicting the PMMA wear depth. According to the comparison between the measured dissipated energy and the energy breaking polymer chains, mechanical dissipated energy is used essentially to transform third body structure and to expel it from the contact between the two materials. Moreover, the experimental results have highlighted the stick-slip phenomenon. Lastly, Attenuated Total Reflectance-Fourier Transform InfraRed, ATR-FTIR, and Reflection Absorption-Fourier Transform InfraRed, RA-FTIR have shown that PMMA debris configuration and conformation have changed after wear against 316L SS. The driving force of these changes seems to be the acid-base interactions between PMMA and hydroxyl groups of the stainless steel surface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Wet and Dry Conditions on Wear Behavior of Amorphous Coating of Fe-Cr-Mo-Nb-C-B

Recently, wear resistant properties of metallic glasses has attracted a lot of interest. Because the surface of metallic glasses are prone to phase transformation, finding the effects of test condition on structure and wear behavior of metallic glasses is important. In this research, by using an automated electrospark deposition (ESD), a layer of Fe51Cr18Mo7B16C4Nb4 was deposited on AISI 316l s...

متن کامل

Denture base polymers, poly methyl methacrylate improved using free radical copolymerization

Poly methyl methacrylate (PMMA) is the most common material used in Prosthodontics. Several studies indicate a breakdown of the number of very high resin bases after 2 to 3 years to avoid breaking bass and several attempts have been made, such as altering the chemical structure of resin by adding causes cross linking or copolymerization. The innovative method for improving the physical properti...

متن کامل

Friction Stir Welding؛ Material Flow؛ Heat Generation؛ Thermal Simulation؛ Poly methyl methacrylate (PMMA)

In this study, the effects of linear and rotational speed of the friction stir welding tool was investigated on the heat generation and distribution at surface and inside of workpiece, material flow and geometry of the welding area of poly methyl methacrylate (PMMA) workpiece. The commercial CFD Fluent 6.4 software was used to simulation of the process with computational fluid dynamic technique...

متن کامل

Modeling fretting-corrosion wear of 316L SS against poly(methyl methacrylate) with the Point Defect Model: Fundamental theory, assessment, and outlook

This work aims at investigating experimentally fretting corrosion, that is, corrosion induced by friction of AISI 316L SS against poly(methyl methacrylate) under small displacements, and subsequently using the data to model wear. The observed wear on the stainless steel has been modeled using the Point Defect Model (PDM). The originality of this approach in applying the PDM to fretting corrosio...

متن کامل

The Release of Residual Monomeric Methyl Methacrylate in Human Saliva after Using Acrylic Dentures

The Release of Residual Monomeric Methyl Methacrylate in Human Saliva after Using Acrylic Dentures Dr. AH. Alehavaz* - Dr. D. Qujeq** - Dr. A. Babapour*** *- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry – Babol University of Medical Sciences. **- Associate Professor of Biochemistry and Biophysics Dept. – Babol University of Medical Sciences. ***- Dentist. Background and Ai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017