The locus of fixation in strabismic amblyopia changes with increasing effort of recognition as assessed by scanning laser ophthalmoscope.

نویسندگان

  • Kirsten Siepmann
  • Jens Reinhard
  • Volker Herzau
چکیده

PURPOSE We performed a qualitative assessment of fixation behaviour in relation to the fovea in patients with strabismic amblyopia. METHODS The fixation of 25 patients with strabismic amblyopia was examined using a scanning laser ophthalmoscope (SLO). A digital frame grabber board was programmed to scan onto the patient's retina single solid black discs of 5, 10 and 15 degrees in diameter and Landolt Cs in different orientations and corresponding to a visual acuity (VA) of 0.01-0.2 in European decimals. The relative position of the fovea was video-recorded. Fifty video fields per second were plotted as x/y (fixational positions in relation to the fovea) and x/t (motion over time) graphs. RESULTS Three main groups of patients were seen. Group 1 (n = 6), with a VA of < 0.1, showed a grossly eccentric and unstable locus of fixation independent of size/type of test stimulus used. Group 2 (n = 15), with VA of 0.1-0.8, initially used an eccentric retinal area for fixation that, however, shifted to the fovea with decreasing size and increasing detail of the target for fixation. Group 3 (n = 4), with VA of 0.3-0.8, had stable central fixation throughout. CONCLUSIONS We speculate that the reduced VA associated with strabismic amblyopia is due to a defective motor control of fixation that can be modulated by recognitional effort.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of the Scanning Laser Ophthalmoscope in the Evaluation of Amblyopia

Purpose: The purpose of this study was to evaluate amblyopic patients with scanning laser ophthalmoscope microperimetry to determine whether the scanning laser ophthalmoscope data provide useful information in our understanding of amblyopia and assess its utility in the evaluation of amblyopic patients. Methods: In this retrospective case-series, clinical data of 46 patients with amblyopia were...

متن کامل

Saccadic latency in amblyopia

We measured saccadic latencies in a large sample (total n = 459) of individuals with amblyopia or risk factors for amblyopia, e.g., strabismus or anisometropia, and normal control subjects. We presented an easily visible target randomly to the left or right, 3.5° from fixation. The interocular difference in saccadic latency is highly correlated with the interocular difference in LogMAR (Snellen...

متن کامل

A new model of strabismic amblyopia: Loss of spatial acuity due to increased temporal dispersion of geniculate X-cell afferents on to cortical neurons

Although the neural locus of strabismic amblyopia has been shown to lie at the first site of binocular integration, first in cat and then in primate, an adequate mechanism is still lacking. Here we hypothesise that increased temporal dispersion of LGN X-cell afferents driven by the deviating eye onto single cortical neurons may provide a neural mechanism for strabismic amblyopia. This idea was ...

متن کامل

Retinal nerve fiber layer thickness in human strabismic amblyopia.

BACKGROUND AND PURPOSE Amblyopia is characterized by histopathological changes in the visual cortex and lateral geniculate nucleus. In the retina, however, no abnormalities have yet been reported. The purpose of this study was to compare the nerve fiber layer (NFL) thickness in the amblyopic eye with that in the sound eye of patients with strabismic amblyopia. As a practical implication, we inv...

متن کامل

Slow control of eye position in strabismic amblyopia.

Unsteady and eccentric monocular fixation were examined in subjects with strabismic amblyopia. Records of horizontal components of unsteady fixation by amblyopic eyes were characterized by abnormally large saccades and a nasalward bias for slow drifts. Typically, these fixational movements aligned the retinal image on an eccentric nasal retinal region. The presence of a slow control mechanism f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta ophthalmologica Scandinavica

دوره 84 1  شماره 

صفحات  -

تاریخ انتشار 2006