Magnetic resonance imaging
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES Convincing evidence supporting the use of magnetic resonance imaging (MRI) as an effective tool for evaluating cervical sagittal alignment is lacking. This study aims to analyze the differences and correlations between cervical sagittal parameters on x-ray and MRI in patients with cervical disc herniation and to determine whether MRI could substitute for cervical x-ray for measurement of cervical sagittal parameters. METHODS One hundred forty-three adults with cervical disc herniation were recruited. Each patient had both an x-ray and MRI examination of the cervical spine. The cervical sagittal parameters were measured and compared on x-ray and MRI including: C2-C7 Cobb angle, C2-C7 sagittal vertical axis (C2-C7 SVA), cervical tilt (CT), T1 Slope (T1S), and neck tilt (NT). The data were analyzed using a paired-samples t test, a Pearson correlation test, and linear regression. RESULTS The values of C2-C7 Cobb angle, C2-C7 SVA, CT and T1S on X-ray were larger than those on MRI (P < .05) and NT on X-ray was smaller than that on MRI (P < .05). Each of the cervical sagittal parameters had a significant correlation with the corresponding one on MRI (r = 0.699, 0.585, 0.574, 0.579 and 0.613, respectively) (C2-C7 Cobb MRI = 0.957 + 0.721 C2-C7 Cobb X, C2-C7 SVA MRI = 6.423 + 0.500 C2-C7 SVAX, CT MRI = 3.121 + 0.718 CTX, T1S MRI = 7.416 + 0.613 T1SX, NT MRI = 22.548 + 0.601 NTX). CONCLUSION Although MRI and x-ray measurements of cervical sagittal parameters were different, there were significant correlations between the results. MRI could be used to evaluate the sagittal balance of the cervical spine with great reliability.
منابع مشابه
Use of Magnetic Resonance Imaging in Food Quality Control: A Review
Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملApplication of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period
To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...
متن کاملA New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...
متن کامل