The human sacrum and safe approaches for screw placement.

نویسندگان

  • Candan Arman
  • Sait Naderi
  • Amaç Kiray
  • Funda Taştekin Aksu
  • Hakan Sinan Yilmaz
  • Süleyman Tetik
  • Esin Korman
چکیده

The human sacrum is the target of lumbosacral instrumentation and decompression procedures. Such surgical interventions require detailed knowledge of the anatomy of the human sacrum. The aim of this study was to measure surgically relevant parameters. Several factors, including the one-piece composition of the sacrum, the angles of the sacral pedicles and the anteroposterior diameter of the sacral vertebral bodies distinguish the sacrum from other parts of spine. Thirty-two measurements of shape, angles and distances between parts were taken of the sacra of 100 adult West Anatolian people using a Vernier caliper accurate to 0.1 mm and goniometer. According to this morphometric study, when measured from the sagittal, the S1 facet angle was measured as 35.71 degrees +/-9.59 and 34.70 degrees +/-9.66, the sacral pedicle anteromedial screw trajectory angle was 35.65 degrees +/-4.73 and 31.95 degrees +/-3.95 and the anterolaterally oriented sacral wing screw trajectory angle was 32.65 degrees +/-3.51 and 29.10 degrees +/-3.14, on the right and left sides, respectively. The distance of the midline oriented S1 pedicle screw was 51.12 mm and 51.26 mm on the right and left side, respectively. The distance for sacral wing oriented screw placement was 50.13 mm and 50.46 mm on the right and left side, respectively. The anteroposterior and transverse diameter of the sacral spinal canal were 21.81 mm and 31.31 mm, respectively. Thus, this study describes anatomical specifications of the sacrum. These defined morphometric details should be taken into consideration during surgical procedures. This study also describes anatomical landmarks which will allow injury of the sacrum during surgery to be avoided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracanal Sacral Nerve Impingement Following Percutaneous Iliosacral Screw Pelvic Fixation

Percutaneous iliosacral screws are useful in treating vertical posterior pelvic fractures and iliosacral disruptions. Iliosacral screws are far less invasive than spinopelvic fixation, and result in much lower morbidity. However, safe placement of the iliosacral screws is technically difficult and highly dependent on fracture reduction and adequate fluoroscopy. Inaccurate placement can result i...

متن کامل

Anatomic study on the placement of pedicle screw at the sacrum

To investigate the feasibility and safe zone of S1-4 for sacral screw placement, a total of 62 adult patients spiral computed tomography images of pelvis were analyzed and reconstructed using Mimics version 15.0 software. The safe zone of the pedicle screws were calculated, the entry points of sacral pedicle at S1-S4 were determined, and the screw trajectory, length, width and angle was measure...

متن کامل

Pedicle morphology of the first sacral vertebra

Received 4 April 2003; accepted 24 April 2003 ABSTRACT Posterior transpedicular screw fixation has been widely used for the management of unstable lumbosacral spine caused by trauma, degenerative conditions, congenital defects and neoplasms. Knowledge of the pedicle diameters of the first sacral vertebra is crucial for safe placement of the screws. Thirty dry sacral specimens (18 male, 12 femal...

متن کامل

Evidence-based support for S1 transpedicular screw entry point modification

BACKGROUND In the literature, 'below and lateral to the superior S1 facet' is defined as the basic technique for screw introduction. Until a recently published modification, no analysis for alternative starting point has been proposed nor evaluated, although some surgeons claim to use some modifications. In this study, we analyse the data from anatomical and radiological studies for optimal sta...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia

دوره 16 8  شماره 

صفحات  -

تاریخ انتشار 2009