Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

نویسندگان

  • Mi-Jung Yun
  • Young-Chan Jeon
  • Chang-Mo Jeong
  • Jung-Bo Huh
چکیده

PURPOSE The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with α-level of 0.05. RESULTS 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n = 40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral dig...

متن کامل

مقایسه تطابق کراون‌های سرامیکی فلدسپاتیک تهیه شده از روی قالب سیلیکون افزایشی و کست گچی به وسیله دستگاه CAD-CAM

  Background and Aims: Marginal fit is one of the key factors in the success of fixed restoration. The aim of this study was to evaluate the fitness of feldespatic crowns made from additional silicon impression and gypsum cast by CAD/CAM.   Materials and Methods: 10 intact extracted upper premolar teeth were used for this experimental study. After preparation of the mounted teeth with radial sh...

متن کامل

A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique

A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique Dr. M. Farzin *- Dr. F. Bahrani ** - Dr. A. Zareie *** *Assistant Professor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences. **Clinical Instructor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences....

متن کامل

بررسی میزان gap و overhang در ناحیه finish line کوپینگ‌های تهیه شده با سه روش ریختگی با دو نوع آلیاژ در ایمپلنت‌های ITI

Background and Aim: An important criterion for success assessment of implant-supported prostheses is marginal fit. Vertical and horizontal discrepancy can result in loosening of the prosthetic screw, crestal bone resorption, peri-implantitis and loss of osseointegration. Despite careful attention to waxing, investing, and casting, marginal discrepancies are inevitable. The aim of this study was...

متن کامل

Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling.

OBJECTIVES The aim of the present study was to compare the fit of all-ceramic crowns fabricated from intraoral digital impressions with the fit of all-ceramic crowns fabricated from silicone impressions. METHODS Twenty patients agreed to take part in the study to receive two Lava crowns each for the same preparation. One crown was fabricated from intraoral scans using the Lava Chairside Oral ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017