Arsenic release provided by MTA and Portland cement.

نویسندگان

  • Marco Antonio Hungaro Duarte
  • Ana Claudia Cardoso De Oliveira Demarchi
  • José Carlos Yamashita
  • Milton Carlos Kuga
  • Sylvio De Campos Fraga
چکیده

OBJECTIVE The aim of the present study was to determine the release of arsenic from 2 gray Portland cements, a white Portland cement, and 2 MTAs (ProRoot and MTA-Angelus). STUDY DESIGN The materials were manipulated and placed in plastic tubes, and the tubes were immersed in glass flasks containing water with grade reagent, pH 5.0. After 3 and 168 h, the water in which the material had been immersed was analyzed regarding the presence of arsenic by atomic absorption spectrophotometry with hydride generation. RESULTS The levels of arsenic released were similar for Portland cements and MTAs, and were well below those considered to be harmful. CONCLUSIONS MTA and Portland cements showed very low arsenic presence. The results suggest that MTAs and Portland cements are safe for use in clinical practice in terms of the presence of arsenic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Presence of arsenic in different types of MTA and white and gray Portland cement.

OBJECTIVE The presence of arsenic in various types of mineral trioxide aggregate (MTA) and Portland cements were evaluated to verify if they comply with the ISO-recommended limit for water-based cements of 2 mg arsenic/kg material. STUDY DESIGN An amount of 5 mL of hydrochloric acid was added to 2 g each of MTA and Portland cement to be analyzed. After 15 minutes, the material was filtered an...

متن کامل

Analysis of heavy metal contents in gray and white MTA and 2 kinds of Portland cement: a preliminary study.

OBJECTIVE The levels of 10 heavy metals (arsenic, bismuth, cadmium, chromium, copper, iron, lead, manganese, nickel, and zinc) in gray Portland cement (GPC), white Portland cement (WPC), gray MTA (GMTA), and white MTA (WMTA) were analyzed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). STUDY DESIGN One gram of each material was digested with 80 degrees C "aqua-regia" (7 ...

متن کامل

Evaluation of physico-chemical properties of Portland cements and MTA.

The purpose of this study was to evaluate the hydrogenionic potential and electrical conductivity of Portland cements and MTA, as well as the amount of arsenic and calcium released from these materials. In Teflon molds, samples of each material were agitated and added to plastic flasks containing distilled water for 3, 24, 72 and 168 h. The results were analyzed with a Kruskal-Wallis non-parame...

متن کامل

Arsenic content in Portland cement: a literature review.

Portland cement (PC) is a hydraulic binding material widely used in the building industry. The main interest in its use in dentistry is focused on a possible alternative to mineral trioxide aggregate (MTA) because PC is less expensive and is widely available. In dentistry, PC has been used in dental procedures such as pulpotomy, pulp capping, repair of root perforation and root-end filling. The...

متن کامل

Comments on "arsenic release provided by MTA and Portland cement" by Duarte MA, et al.

The authors presented their data from atomic absorption tests, stating that the cements released less than 0.0007 ppm of arsenic after a week of soaking in weakly acidic solution. That is, the cements released 0.7 ppb from their worst sample. My first comment is on the atomic absorption technique for arsenic. According to the EPA method 7062 for detection of arsenic by atomic absorption using s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics

دوره 99 5  شماره 

صفحات  -

تاریخ انتشار 2005