An anatomical study of the entry point in the greater trochanter for intramedullary nailing.

نویسندگان

  • K Farhang
  • R Desai
  • J H Wilber
  • D R Cooperman
  • R W Liu
چکیده

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined. The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded. The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (sd 4.0) and 4.6 mm (sd 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (sd 4.6) and 6.4 mm (sd 4.6), respectively. Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed, locked intramedullary nailing of pediatric femoral shaft fractures through the tip of the greater trochanter.

BACKGROUND Closed femoral nailing is universally accepted as the treatment of choice in almost all diaphyseal femoral fractures in adults. Numerous authors reported favorable results applying the same surgical technique in the adolescent patient group. Nevertheless, reports of complications such as avascular necrosis and alteration of the proximal femoral anatomy have dampened the initial enthu...

متن کامل

Locked rigid antegrade intramedullary nailing of adolescent femoral fractures using a lateral trochanteric entry point.

The purpose of this study is to present our experience of treating adolescent femoral fractures using a locked intramedullary nail with a lateral trochanteric entry point. We retrospectively reviewed 15 femoral fractures in 13 adolescents who were treated in our unit between 2011 and 2014. Data collected included patient demographics, mechanism of injury, type of fracture, associated injuries, ...

متن کامل

Incidence of Avascular Necrosis of the Femoral Head After Intramedullary Nailing of Femoral Shaft Fractures

The goal of this study was to determine the incidence of avascular necrosis of the femoral head (AVNFH) after intramedullary nailing of femoral shaft fractures and to identify risk factors for developing AVNFH.We retrospectively reviewed all patients with femoral shaft fractures treated with antegrade intramedullary nailing at 10 institutions. Among the 703 patients enrolled, 161 patients were ...

متن کامل

Comparing Entry Points for Antegrade Nailing of Femoral Shaft Fractures.

The optimal entry point for antegrade intramedullary nailing of femoral shaft fractures remains controversial. The purpose of this systematic review was to determine whether there is a difference in operative parameters, healing, and functional outcome when comparing the greater trochanter (GT) and piriformis fossa (PF) entry points. A systematic search of multiple databases and 3 major orthope...

متن کامل

Correlation of Trochanter-Shaft Angle in Selection of Entry Site in Antegrade Intramedullary Femoral Nail

Background. Selection of entry point for nail insertion is controversial and lack firm anatomical basis. The study is done to analyze the proximal anthropometry of femur and measure the Trochanter-Shaft Angle to find its relation and significance in selection of entry point for antegrade uniplanar femoral nail. Materials and Methods. Study involves the measurement of trochanter-shaft angle and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The bone & joint journal

دوره 96-B 9  شماره 

صفحات  -

تاریخ انتشار 2014