Management of complicated multirecurrent pterygia using multimicroporous expanded polytetrafluoroethylene
نویسندگان
چکیده
AIMS To evaluate the efficiency of multimicroporous expanded polytetrafluoroethylene (e-PTFE) insertion in complicated multirecurrent pterygia. METHODS A total of 62 eyes from 62 patients with a multirecurrent pterygium associated with symblepharon or motility restriction-related binocular diplopia were recruited. All eyes underwent pterygia excision followed by application of 0.033% mitomycin C, amniotic membrane transplantation and conjunctival limbal autograft. Multimicroporous e-PTFE was then inserted intraoperatively in 30 eyes between the transplanted amniotic membrane and the conjunctiva (group A), but not inserted in the other 32 eyes (group B). The main outcome measures were symblepharon formation, motility restriction, binocular diplopia, subjective score of conjunctival hyperaemia and postoperative pterygium recurrence. RESULTS In the mean follow-up period of 17.2±2.3 months, symblepharon formation, motility restriction, diplopia and conjunctival hyperaemia were significantly improved after surgery in group A patients (p=0.000, 0.000, 0.008 and 0.000, respectively). Postoperative symblepharon formation, motility restriction and conjunctival hyperaemia were significantly less in group A compared to group B (p=0.024, 0.027 and 0.000, respectively). After surgery, corneal recurrence developed in one eye (3.3%) from group A, which was significantly lower than the eight eyes (25%) from group B (p=0.027). CONCLUSIONS Multimicroporous e-PTFE insertion may provide a novel approach for treating intractable complicated multirecurrent pterygia.
منابع مشابه
New grading system to improve the surgical outcome of multirecurrent pterygia.
OBJECTIVE To report a new grading system and surgical outcome by sealing the gap between the conjunctiva and Tenon capsule. METHODS A total of 32 eyes of 30 patients with pterygia were managed at the Ocular Surface Center from January 1, 2002, through December 31, 2010. The eyes were consecutively operated on by recession; sealing of the gap; covering of exposed medial rectus muscle by amniot...
متن کاملDuplex Scanning of Expanded Polytetrafluoroethylene Dialysis Shunts : Impact on Patient Management and Graft Survival
The steady decline with time in patency of expanded polytetrafluoroethylene (e-PTFE) dialysis shunts led to a trial protocol of postimplantation surveillance to identify those grafts at risk for thrombosis. Duplex scanning is a noninvasive, reproducible method of monitoring anatomic and hemodynamic aspects of graft function that provides the surgeon with an opportunity for early operative inter...
متن کاملDual-porosity expanded polytetrafluoroethylene implants for lip, nasolabial groove, and melolabial groove augmentation.
OBJECTIVE To evaluate the clinical outcomes with the use of a dual-porosity expanded polytetrafluoroethylene implant for midfacial rejuvenation. DESIGN An institutional review board-approved retrospective chart review was conducted of all patients who underwent implantation with the dual-porosity expanded polytetrafluoroethylene implant between 2001 and 2005. RESULTS A total of 170 patients...
متن کاملDuraplasty in the posterior fossa using a boat-shaped sheet of expanded polytetrafluoroethylene.
Application of sutures between expanded polytetrafluoroethylene (ePTFE) dural substitutes and the dura mater is often frustrating in posterior fossa surgery because of the difficulty in holding the elastic graft in a deep and narrow field. To resolve this problem, we have developed a boat-shaped graft made from a triangular ePTFE sheet by pinching each angle using a suture. Formation of standin...
متن کاملHomemade expanded-polytetrafluoroethylene flexible mitral annuloplasty ring.
A homemade mitral annular prosthesis has been developed using expanded-polytetrafluoroethylene material. It is safe in that it avoids the risk of prosthesis wrinkle when stitches are tied. Simultaneously, it is strong enough to prevent future stretching and rupture. This device has been implanted in 60 patients with good and stable results at 42 months of follow-up. Our flexible mitral annular ...
متن کامل