Orbital floor fractures: a retrospective review of 45 cases at a tertiary health care center.

نویسندگان

  • Chun H Rhim
  • Thomas Scholz
  • Ara Salibian
  • Gregory R D Evans
چکیده

The purpose of this retrospective study was to investigate treatment options for orbital floor fractures at a Level 1 Trauma Center in Southern California. A review of 45 cases of isolated orbital floor fractures treated at the University of California at Irvine between February 2004 and April 2007 was done. Patients were retrospectively analyzed for gender, age, mechanism of injury, associated facial injuries, presenting symptoms, method of treatment, and postoperative complications. Thirty-six male patients and nine female patients were treated. Motor vehicle collision (26/45) was the most common cause of injury, and the mean age of the patients was 35.5 years (range: 15-81 years). Ecchymosis surrounding the orbital tissue was the most common presentation (38/45). Diplopia was present in 8 of 45 patients, with 1 patient requiring urgent decompression for retrobulbar hematoma. Forty-three patients underwent surgical repair; 40 underwent transconjunctival approach with lateral canthotomy; 17 underwent reconstruction with porous polyethylene Medpor (Porex Surgical, Inc., College Park, GA.); and 26 underwent reconstruction with a titanium mesh plate. Immediate postoperative complications included 12 patients with infraorbital numbness, 3 with diplopia, 1 with cellulitis, and 1 with ectropion with a subcilliary approach. Average timing of surgery of our study was 4.94 days (range, 1-20 days). Orbital floor fracture management has changed significantly over the past few decades with the introduction of new internal fixation methods and new materials for reconstructing orbital floor defects. Recommendations for surgical intervention on orbital floor fractures mostly depend on clinical examination and imaging studies. Consequences of inadequate repair of orbital floor fractures can lead to significant facial asymmetry and visual problems. Both porous polyethylene and titanium plates are effective tools for reconstructing the orbital floor. Our review demonstrates that orbital floor fractures can be repaired safely with minimal postoperative complications and confirms that transconjunctival approach to orbital floor is an effective way for exposure and prevention of ectropion that can be seen with other techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concomitant ocular injuries with orbital fractures.

BACKGROUND AND OBJECTIVES The orbital floor may fracture alone, and the fracture is then defined as "pure"; when there is a rim involvement, the fracture may be defined as "impure". Controversy exists as to the pathophysiology of orbital floor fractures and the incidence of orbital rim involvement. The purpose of this retrospective review was to determine the incidence of purity in orbital floo...

متن کامل

Use of copolymer polylactic and polyglycolic acid resorbable plates in repair of orbital floor fractures.

The fractures of the orbital floor are common after craniofacial trauma. Repair with resorbable plates is a viable reconstructive option; however, there are few reports in the literature. This study describes our experience using copolymer polylactic and polyglycolic acid (PLLA/PGA) orbital reconstruction plates (LactoSorb, Lorenz Surgical, Jacksonville, FL) in 29 cases of the orbital floor fra...

متن کامل

Infraorbital Nerve Block for Isolated Orbital Floor Fractures Repair: Review of 135 Consecutive Cases

BACKGROUND Orbital blowout fractures can be managed by several surgical specialties including plastic and maxillofacial surgery, otolaryngology, and ophthalmology. Recommendations for surgical fracture repair depend on a combination of clinical and imaging studies to evaluate muscle/nerve entrapment and periorbital tissue herniation. METHODS The aim of this study was to verify the applicabili...

متن کامل

Etiology of orbital fractures at a level I trauma center in a large metropolitan city☆

BACKGROUND/PURPOSE Orbital fractures are a common facial fracture managed by multiple surgical specialties. Methods: A retrospective review of the electronic medical records of patients (age, 18-85 years) presenting to Northwestern Memorial Hospital and Northwestern Medical Faculty Foundation in Chicago, IL, USA with International Classification of Diseases, Ninth Revision codes for facial frac...

متن کامل

Orbital blowout fractures and race.

PURPOSE To examine the type of orbital blowout fracture and its variation with race. DESIGN Retrospective review of computed tomography (CT) scans and demography in an unselected cohort of patients with orbital blowout fractures. PARTICIPANTS Patients with a high-resolution CT scan of adequate quality for analysis who presented with an orbital blowout fracture to the Orbital Clinic at Moorf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Craniomaxillofacial trauma & reconstruction

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2010