Development of pulmonary blood flow evaluation method with a dynamic flat-panel detector: quantitative correlation analysis with findings on perfusion scan.

نویسندگان

  • Rie Tanaka
  • Shigeru Sanada
  • Masaki Fujimura
  • Masahide Yasui
  • Norio Hayashi
  • Shiro Tsuji
  • Hiroyuki Okamoto
  • Yuko Nanbu
  • Osamu Matsui
چکیده

Pulmonary blood flow is reflected in dynamic chest radiographs as changes in X-ray translucency, i.e., pixel values. Thus, decreased blood flow should be observed as a reduction of the variation of X-ray translucency. We performed the present study to investigate the feasibility of pulmonary blood flow evaluation with a dynamic flat-panel detector (FPD). Sequential chest radiographs of 14 subjects were obtained with a dynamic FPD system. The changes in pixel value in each local area were measured and mapped on the original image by use of a gray scale in which small and large changes were shown in white and black, respectively. The resulting images were compared to the findings in perfusion scans. The cross-correlation coefficients of the changes in pixel value and radioactivity counts in each local area were also computed. In all patients, pulmonary blood flow disorder was indicated as a reduction of changes in pixel values on the mapping image, and a correlation was observed between the distribution of changes in pixel value and those in radioactivity counts (0.7 <or= r, 3 cases; 0.4 <or= r < 0.7, 7 cases; 0.2 <or= r < 0.4, 4 cases). The results indicated that the distribution of changes in pixel value could provide a relative measure related to pulmonary blood flow. The present method is potentially useful for evaluating pulmonary blood flow as an additional examination in conventional chest radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Title Pulmonary blood flow evaluation using a dynamic flat - panel detector

Purpose Pulmonary ventilation and circulation dynamics are reflected on fluoroscopic images as changes in X-ray translucency. The purpose of this study was to investigate the feasibility of non-contrast functional imaging using a dynamic flat-panel detector (FPD). Methods Dynamic chest radiographs of 20 subjects (Abnormal, n=12; Normal, n=8) were obtained using the FPD system. Image analysis wa...

متن کامل

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

Evaluation of an Acute Stroke Patient with Flat Detector CT Prior to Mechanical Thrombectomy

Flat panel detectors have revolutionized tomographic imaging in the angio suite. Recent developments in hardware and software have improved soft tissue resolution and acquisition time even further, enabling soft-tissue and perfusion imaging within the angio suite. The so called “one-stop-shop” stroke imaging with flat panel detector computed tomography (FDCT) will significantly improve door to ...

متن کامل

[Pulmonary functional diagnostic imaging using a dynamic flat-panel detector: comparison with findings in pulmonary scintigraphy].

Pulmonary ventilation and circulation dynamics are reflected on dynamic chest radiographs as changes in X-ray translucency,i.e., pixel values. The present study was performed to develop a pulmonary functional evaluation method based on the changes in pixel value, and to investigate the clinical usefulness of our method. Sequential chest radiographs of 20 subjects (abnormal,n=12; normal,n=8) dur...

متن کامل

Utilizing flat-panel detector parenchymal blood volume imaging (FD-PBV) for quantitative kidney perfusion analysis during the process of percutaneous transluminal renal angioplasty (PTRA)

Rationale: Traditional digital subtraction angiography (DSA) provides lumen morphology of renal artery as indicators for vascular patency in patients with renal artery stenosis (RAS). It, however, lacks hemodynamic information toward target kidney. To solve this shortcoming, a novel technique, flat-panel detector parenchymal blood volume imaging (FD-PBV), is introduced, which is able to evaluat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiological physics and technology

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2010