Harmonic Impact of Residential Type Photovoltaic Inverters on 11kV Distribution System

نویسندگان

  • A. A. Latheef
  • V. J. Gosbell
  • V. Smith
چکیده

The number of installations of photovoltaic solar panels and associated inverter systems within residential premises is increasing. As these systems incorporate a power electronics front end, they will have an influence on the quality of supply in regards to voltage harmonics. This paper investigates the harmonic impact on an 11kV distribution system due to the installation of residential type grid connected photovoltaic inverter systems (PVIS). To characterise the aggregated harmonic current spectrum contributed from the low voltage system, a typical inverter spectrum is utilised. Conventional harmonic modelling techniques are applied to determine a medium voltage system model and resulting network wide harmonic voltages for various penetration levels of residential type photovoltaic inverter systems. Based on this study, a recommendation is made for acceptable penetration levels to limit the harmonic impact of grid connected photovoltaic inverter systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Harmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR

The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...

متن کامل

Power Quality Issues Concerning Photovoltaic Generation in Distribution Grids

Unregulated utilization of renewable generation including residential photovoltaic (PV) systems can have a significant impact on load characteristics in distribution networks. For improving PV generation capabilities, power quality aspects have to be coordinated with present load characteristics. This paper discusses the harmonic content of PV generation and the influence to power quality indic...

متن کامل

PR Current Control with Harmonic Compensation in Grid Connected PV Inverters

This paper presents a study on Proportional Resonant (PR) current control with additional PR harmonic compensators for Grid Connected Photovoltaic (PV) Inverters. Both simulation and experimental results will be presented. Testing was carried out on a 3kW Grid-Connected PV Inverter which was designed and constructed for this research. Keywords—Inverters, Proportional-Resonant Controllers, Harmo...

متن کامل

Single phase pv inverter pdf

A proprietary data monitoring receiver has been integrated into the single phase solar inverter and aggregates the power optimizer performance data from each. single phase solar inverter price A single-phase grid connected transformerless photovoltaic PV inverter for. ABSTRACT In this paper the issue of control strategies for single-stage photovoltaic PV inverter is addressed. single phase pv i...

متن کامل

Comparative Study of Harmonic Analysis in Different Levels of Symmetrical Cascaded H-bridge Multilevel Inverter for Photovoltaic System

Photovoltaic energy conversion becomes main focus of many researches due to its promising potential as source for future electricity and has many advantages than the other alternative energy sources like wind, solar, ocean, biomass, geothermal etc. In Photovoltaic power generation system multi level inverters can be used as an alternative configuration for the dc to ac inverter. Diode clamped i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006