Pulsed electron avalanche knife: new technology for cataract surgery.
نویسندگان
چکیده
BACKGROUND The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, "cold" and traction-free tissue dissection. AIM To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery. METHODS The study included five children with congenital cataracts, two patients with advanced senile cataracts, six adults with mature cataracts, three of them with posterior iris synechia, three patients with post-traumatic cataracts with zonulolysis, one patient with intumescent traumatic cataract and three patients with massive anterior capsule opacification. Anterior and posterior capsulotomies, iris synechiolysis, dissection of anterior capsule opacification and fibrotic scar tissue were performed. PEAK-fc was set at voltages of 500-700 V, pulse duration of 0.1 m and repetition rate of 40-100 Hz. RESULTS Anterior and posterior capsulotomies were successfully and safely performed in all eyes. The edges of capsulotomies appeared sharp, showing only limited collateral damage. PEAK-fc worked best by just gently touching the capsule, thereby avoiding tractional forces or pressure on the lens capsule. Posterior iris synechiae could be released and anterior capsule opacification was dissected without complications. CONCLUSIONS PEAK-fc is a very helpful cutting device for complicated cases of cataract surgery, especially for mature and congenital cataracts, traumatic zonulolysis or anterior segment complications after intraocular inflammation.
منابع مشابه
Anterior capsulotomy with a pulsed-electron avalanche knife.
PURPOSE To evaluate a new pulsed-electron avalanche knife design for creating a continuous curvilinear capsulotomy (CCC) and compare the CCC with a mechanical capsulorhexis. SETTING Department of Ophthalmology, Stanford University, Stanford, California, USA. METHODS In this study, CCCs were created in freshly enucleated bovine eyes and in rabbit eyes in vivo. The cutting velocity was adjust...
متن کاملSURGICAL TECHNIQUES Pulsed electron avalanche knife: new technology for cataract surgery
Background: The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, ‘‘cold’’ and traction-free tissue dissection. Aim: To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery. Methods: The study included five children with congenital cataracts, two patients with advanced senile ca...
متن کاملPulsed electron avalanche knife for capsulotomy in congenital and mature cataract.
The pulsed electron avalanche knife (PEAK-fc, Carl Zeiss Meditec) is an electrosurgical cutting device that allows precise "cold" and traction-free tissue dissection. We describe its applicability and safety for anterior capsulotomy in a child with congenital cataract and an adult patient with mature cataract. The PEAK-fc was set at a voltage of 600 V and a pulse repetition rate of 80 Hz. Anter...
متن کاملPulsed electron avalanche knife (PEAK) for intraocular surgery.
PURPOSE To develop a better and more economical instrument for precise, tractionless, "cold" cutting during intraocular surgery. The use of highly localized electric fields rather than laser light as the means of tissue dissection was investigated. METHODS A high electric field at the tip of a fine wire can, like lasers, initiate plasma formation. Micrometer-length plasma streamers are genera...
متن کاملPulsed electron avalanche knife in vitreoretinal surgery.
PURPOSE To evaluate the advantages, disadvantages, safety, and surgical applicability of the pulsed electron avalanche knife (PEAK-fc), a new electrosurgical knife for "cold" and tractionless cutting, in vitreoretinal surgery. PEAK-fc is equipped with an integrated fiberoptic that makes bimanual procedures in intraocular surgery possible. METHODS A prospective consecutive trial of 18 eyes in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 91 7 شماره
صفحات -
تاریخ انتشار 2007