Incorporation of concentration data below the limit of quantification in population pharmacokinetic analyses
نویسندگان
چکیده
Handling of data below the lower limit of quantification (LLOQ), below the limit of quantification (BLOQ) in population pharmacokinetic (PopPK) analyses is important for reducing bias and imprecision in parameter estimation. We aimed to evaluate whether using the concentration data below the LLOQ has superior performance over several established methods. The performance of this approach ("All data") was evaluated and compared to other methods: "Discard," "LLOQ/2," and "LIKE" (likelihood-based). An analytical and residual error model was constructed on the basis of in-house analytical method validations and analyses from literature, with additional included variability to account for model misspecification. Simulation analyses were performed for various levels of BLOQ, several structural PopPK models, and additional influences. Performance was evaluated by relative root mean squared error (RMSE), and run success for the various BLOQ approaches. Performance was also evaluated for a real PopPK data set. For all PopPK models and levels of censoring, RMSE values were lowest using "All data." Performance of the "LIKE" method was better than the "LLOQ/2" or "Discard" method. Differences between all methods were small at the lowest level of BLOQ censoring. "LIKE" method resulted in low successful minimization (<50%) and covariance step success (<30%), although estimates were obtained in most runs (∼90%). For the real PK data set (7.4% BLOQ), similar parameter estimates were obtained using all methods. Incorporation of BLOQ concentrations showed superior performance in terms of bias and precision over established BLOQ methods, and shown to be feasible in a real PopPK analysis.
منابع مشابه
High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies
A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...
متن کاملHigh-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies
A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...
متن کاملEstimating terminal half life by non-compartmental methods with some data below the limit of quantification
In pharmacokinetic studies it occurs more or less frequently that some measurements are reported to be below the limit of quantification. These data are usually discarded in estimating the terminal half-life by non-compartmental methods. We modify this approach to allow for incorporating data below the quantification limit into the analysis. This is achieved by using maximum likelihood methods ...
متن کاملIndividual and population pharmacokinetic compartment analysis: a graphic procedure for quantification of predictive performance
OBJECTIVES Pharmacokinetic studies are important for optimizing of drug dosing, but requires proper validation of the used pharmacokinetic procedures. However, simple and reliable statistical methods suitable for evaluation of the predictive performance of pharmacokinetic analysis are essentially lacking. The aim of the present study was to construct and evaluate a graphic procedure for quantif...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کامل