Assessment of lower limb alignment: supine fluoroscopy compared with a standing full-length radiograph.

نویسندگان

  • Sanjeev Sabharwal
  • Caixia Zhao
چکیده

BACKGROUND While a full-length standing anteroposterior radiograph of the lower extremity provides the best radiographic method for assessing limb alignment, other methods must be used intraoperatively. We have employed intraoperative fluoroscopy with use of an electrocautery cord to assess limb alignment in the supine patient. METHODS We retrospectively compared the measurements of lower limb alignment that were obtained with use of supine intraoperative fluoroscopy with those that were obtained with use of a full-length standing anteroposterior radiograph of the lower extremity. A single examiner compared 102 sets of supine fluoroscopy images and full-length standing anteroposterior radiographs of the lower extremity to assess mechanical axis deviation and the joint line convergence angle. For the intraoperative fluoroscopic examination, an electrocautery cord was positioned overlying the center of the femoral head and the tibial plafond and an anteroposterior radiograph of the knee was made. The effect of age, gender, diagnosis, body mass index, pelvic height difference, joint line convergence angle, and the magnitude and direction of malalignment (varus or valgus) on the discrepancy in the observed mechanical axis deviation with use of the two methods was assessed. RESULTS The mean absolute difference between the two techniques was 13.4 mm for the measurement of mechanical axis deviation (p < 0.0001) and 2.8 degrees for the joint line convergence angle (p < 0.0001). The correlation coefficient (r) for the measurement of mechanical axis deviation with use of the two radiographic methods was 0.88. An increase in body mass index was associated with a greater magnitude of discrepancy in the measurement of mechanical axis deviation between the two techniques (p = 0.0014). Age, gender, pelvic height difference, and the direction of malalignment had no effect on the discrepancy in the measurement of mechanical axis deviation. Limbs with >2 cm of mechanical axis deviation and those with a joint line convergence angle of >3 degrees on the standing radiograph were significantly more likely to have >10 mm of discrepancy in the measurement of mechanical axis deviation with use of the two imaging techniques (p < 0.005). CONCLUSIONS Intraoperative fluoroscopy with use of the electrocautery cord method is a useful tool for assessing lower limb alignment in patients with a normal body mass index and </=2 cm of mechanical axis deviation and </=3 degrees of joint line convergence angle on the standing anteroposterior radiograph. However, the results obtained with fluoroscopy should be interpreted with caution in patients who are obese or who have substantial residual mechanical axis deviation or pathologic laxity of the knee joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment

UNLABELLED BACKGROUND The purpose of this study was to assess the concurrent validity of alternative measures of frontal plane knee alignment, namely the radiographic anatomic axis and two clinical measures in patients complaining of knee malalignment as compared with the mechanical axis on full-length radiograph of lower limbs. METHODS The knee-alignment angle was measured in 100 knees of...

متن کامل

EOS low-dose radiography: a reliable and accurate upright assessment of lower-limb lengths.

BACKGROUND Children with lower-limb-length discrepancy require repeated radiographic assessment for monitoring and as a guide for management. The need for accurate assessment of length and alignment is balanced by the need to minimize radiation exposure. We compared the accuracy, reliability, and radiation dose of EOS, a novel low-dose upright biplanar radiographic imaging system, at two differ...

متن کامل

Prediction of Body Center of Mass Acceleration From Trunk and Lower Limb Joints Accelerations During Quiet Standing

Purpose: Predicting body Center of Mass (COM) acceleration is carried out with more accuracy based on the acceleration of three joints of lower limb compared to only accounting joints of hip and ankle. Given that trunk movement during quite standing is noticeable, calculating trunk acceleration in model might increase prediction accuracy of COM acceleration. Moreover, in previous research studi...

متن کامل

Using the Anatomical Axis as an Alternative to the Mechanical Axis to Assess Knee Alignment.

The treatment of knee osteoarthritis and the preparation for total knee arthroplasty require repetitive imaging to guide preoperative planning and operative technique. Full-length standing anteroposterior images are the gold standard in assessing the alignment of the limb via the measurement of the mechanical axis of the knee. The anatomical axis can be obtained from a more limited image of the...

متن کامل

Radiographic Assessment of Guided Growth: The Correlation Between Screw Divergence and Change in Anatomic Alignment.

BACKGROUND Assessment of changes in anatomic alignment following guided growth traditionally utilizes full-length standing radiographs which subjects patients to larger radiation doses than does a single anteroposterior radiograph of the knee. In an effort to minimize radiation exposure, the present study sought to determine whether changes in screw divergence (SD) of the 2-hole tension band pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 90 1  شماره 

صفحات  -

تاریخ انتشار 2008