A new portable monitor for measuring odorous compounds in oral, exhaled and nasal air

نویسندگان

  • Naofumi Tamaki
  • Kenta Kasuyama
  • Mitsue Esaki
  • Takara Toshikawa
  • Shun-Ichi Honda
  • Daisuke Ekuni
  • Takaaki Tomofuji
  • Manabu Morita
چکیده

BACKGROUND The B/B Checker®, a new portable device for detecting odorous compounds in oral, exhaled, and nasal air, is now available. As a single unit, this device is capable of detecting several kinds of gases mixed with volatile sulfur compounds (VSC) in addition to other odorous gasses. The purpose of the present study was to evaluate the effectiveness of the B/B Checker® for detecting the malodor level of oral, exhaled, and nasal air. METHODS A total of 30 healthy, non-smoking volunteers (16 males and 14 females) participated in this study. The malodor levels in oral, exhaled, and nasal air were measured using the B/B Checker® and by organoleptic test (OT) scores. The VSCs in each air were also measured by gas chromatography (GC). Associations among B/B Checker® measurements, OT scores and VSC levels were analyzed using Spearman correlation coefficients. In order to determine the appropriate B/B Checker® level for screening subjects with malodor, sensitivity and specificity were calculated using OT scores as an identifier for diagnosing oral malodor. RESULTS In oral and nasal air, the total VSC levels measured by GC significantly correlated to that measured by the B/B Checker®. Significant correlation was observed between the results of OT scores and the B/B Checker® measurements in oral (r = 0.892, p < 0.001), exhaled (r = 0.748, p < 0.001) and nasal air (r = 0.534, p < 0.001). The correlation between the OT scores and VSC levels was significant only for oral air (r = 0.790, p < 0.001) and nasal air (r = 0.431, p = 0.002); not for exhaled air (r = 0.310, p = 0.096). When the screening level of the B/B Checker® was set to 50.0 for oral air, the sensitivity and specificity were 1.00 and 0.90, respectively. On the other hand, the screening level of the B/B Checker® was set to 60.0 for exhaled air, the sensitivity and specificity were 0.82 and 1.00, respectively. CONCLUSION The B/B Checker® is useful for objective evaluation of malodor in oral, exhaled and nasal air and for screening subjects with halitosis. TRIAL REGISTRATION ClinicalTrials.gov: NCT01139073.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارتباط بین غلظت تتراکلرواتیلن در هوای بازدم و سطوح مواجهه فردی در شاغلین خشکشویی

Background: When workplace air monitoring is not sufficient to determine the exposure levels, the determination of compounds and some metabolites in exhaled air and personal exposure levels is considered a practical method for biological monitoring. The aim of this study was to determine the relationship between the concentration of tetrachlorethylene in exhaled air and personal exposure levels...

متن کامل

Characterization of exhaled nitric oxide: introducing a new reproducible method for nasal nitric oxide measurements.

Nitric oxide (NO) is present in the human nasal airways and has been suggested to originate primarily from the paranasal sinuses. The aim of this study was to establish a new and reproducible method for measurement of nasal NO. Through repeated single-breath measurements the intra- and inter-individual variations of NO levels in nasally (into a tightly fitting mask covering the nose) and orally...

متن کامل

Increased amount of nitric oxide in exhaled air of asthmatics.

The presence of nitric oxide (NO) in the exhaled air of humans has recently been described. We wanted to assess at what level exhaled NO originates in normal airways, and to determine whether airway inflammation induces changes in the levels of exhaled NO. Exhaled NO was continuously measured by chemiluminescence technique during normal tidal breathing through the nose or mouth, with a detectio...

متن کامل

Nasal and oral contribution to inhaled and exhaled nitric oxide: a study in tracheotomized patients.

Nitric oxide (NO) is produced at different sites in the human airways and may have several physiological effects. Orally-produced NO seems to contribute to the levels found in exhaled air. Autoinhalation of nasal NO increases oxygenation and reduces pulmonary artery pressure in humans. The aim of this study was to measure the concentration and output of NO during nasal, oral and tracheal contro...

متن کامل

Characterization of Odorous Compounds (VOC and Carbonyl Compounds) in the Ambient Air of Yeosu and Gwangyang, Large Industrial Areas of South Korea

Odorous compounds play an important role in air pollution in industrial areas and the residential areas surrounding them. This study measured the odorous volatile organic compounds (VOC) and carbonyl compounds at Yeosu and Gwangyang, two large industrial areas of South Korea, during four seasons of 2008-2009. Along with these two cities, the same odorous compounds were measured at Suncheon, whi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011