Electron Radiolysis of Ammonium Perchlorate: A Reflectron Time-of-Flight Mass Spectrometric Study.

نویسندگان

  • Sándor Góbi
  • Alexandre Bergantini
  • Andrew M Turner
  • Ralf I Kaiser
چکیده

Thin films of ammonium perchlorate (NH4ClO4) were exposed to energetic electrons at 5.5 K to explore the radiolytic decomposition mechanisms. The effects of radiolysis were monitored on line and in situ via Fourier transform infrared spectroscopy (FTIR) in the condensed phase along with electron impact ionization quadrupole mass spectrometry (EI-QMS) and single-photon photoionization reflectron time-of-flight mass spectrometry (PI-ReTOF-MS) during the temperature-programmed desorption (TPD) phase to probe the subliming molecules. Three classes of molecules were observed: (i) nitrogen bearing species [ammonia (NH3), hydroxylamine (NH2OH), molecular nitrogen (N2), nitrogen dioxide (NO2)], (ii) chlorine carrying molecules [chlorine monoxide (ClO), chlorine dioxide (ClO2), dichlorine trioxide (Cl2O3)], and (iii) molecular oxygen (O2). Decay profiles of the reactants along with the growth profiles of the products as derived from the infrared data were fit kinetically to obtain a reaction mechanism with the initial steps involving a proton loss from the ammonium ion (NH4+) yielding ammonia (NH3) and the decomposition of perchlorate ion (ClO4-) forming chlorate ion (ClO3-) plus atomic oxygen. The latter oxidized ammonia to hydroxylamine and ultimately to nitrogen dioxide. Molecular oxygen and nitrogen were found to be formed via recombination of atomic oxygen and multistep radiolysis of ammonia, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localization and imaging of sialylated glycosphingolipids in brain tissue sections by MALDI mass spectrometry.

In this study, we describe a simple and efficient method for mapping the distribution and localization of all sialylated sphingoglycolipids present in coronal mouse brain sections using a conventional axial matrix-assisted laser desorption/ionization time of flight. A single scan of a histological tissue section gives a complete profile of ganglioside species without derivatization or labeling....

متن کامل

Determination of perchlorate at trace levels in drinking water by ion-pair extraction with electrospray ionization mass spectrometry.

Perchlorate has been added to the U.S. Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). The present work describes the analysis of perchlorate in water by liquid-liquid extraction followed by flow injection electrospray mass spectrometry (ESI/MS). Cationic surfactants, mostly alkyltrimethyl-ammonium salts, are used to ion-pair aqueous perchlorate, forming extra...

متن کامل

Construction and performance test of a multiplexed multistage (MS(n)) time-of-flight mass spectrometer.

A time-of-flight mass spectrometer equipped with two reflectrons was constructed for multiplexed photodissociation tandem mass spectrometry of peptide ions generated by matrix-assisted laser desorption ionization. A linear reflectron was used for high-resolution selection of a precursor ion while a quadratic reflectron was used for product ion analysis. With the photoexcitation of a precursor i...

متن کامل

An ion trap storage/time-of-flight mass spectrometer

An ion trap/time-of-flight (TOF) mass spectrometer combination has been developed in order to combine the storage capabilities of an ion trap with the speed and resolution of a time-of-flight device. The ion trap is an rf quadrupole trap which operates in the total storage mode, i.e., with the dc voltage=0 on the end caps and rf voltage on the ring electrode. The trap has an ion storage time of...

متن کامل

Tandem time-of-flight mass spectrometer for photodissociation of biopolymer ions generated by matrix-assisted laser desorption ionization (MALDI-TOF-PD-TOF) using a linear-plus-quadratic potential reflectron.

A tandem time-of-flight mass spectrometer for the study of photodissociation of biopolymer ions generated by matrix-assisted laser desorption ionization was designed and constructed. A reflectron with linear and quadratic (LPQ) potential components was used. Characteristics of the LPQ reflectron and its utility as the second stage analyzer of the tandem mass spectrometer were investigated. Perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of physical chemistry. A

دوره 121 20  شماره 

صفحات  -

تاریخ انتشار 2017