Klystron Gun Arcing and Modulator Protection

نویسنده

  • S. L. Gold
چکیده

The demand for 500 kV and 265 amperes peak to power an X-Band klystron brings up protection issues for klystron faults and the energy dumped into the arc from the modulator. This situation is made worse when more than one klystron will be driven from a single modulator, such as the existing schemes for running two and eight klystrons. High power pulsed klystrons have traditionally be powered by line type modulators which match the driving impedance with the load impedance and therefore current limit at twice the operating current. Multiple klystrons have the added problems of a lower modulator source impedance and added stray capacitance, which converts into appreciable energy at high voltages like 500kV. SLAC has measured the energy dumped into klystron arcs in a single and dual klystron configuration at the 400 to 450kV level and found interesting characteristics in the arc formation. The author will present measured data from klystron arcs powered from line-type modulators in several configurations. The questions arise as to how the newly designed solid-state modulators, running multiple tubes, will react to a klystron arc and how much energy will be dumped into the arc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Present Status of Rf Gun Project at Waseda University

We have conducted the research project named “HighTech Research Center Project” at Waseda University, which is supported by the Ministry of Education, Culture, Sports, Science and Technology. In this project, a laser photo-cathode rf-gun with 1.6 acceleration cells with Mg cathode has been installed for production of low emittance and short bunched electron beam. Main parts of rf source for the...

متن کامل

Operational Experience with Slac Energy Upgrade ’

To produce energies of over 50 GeV for SLC, all klystron stations on the accelerator ue being upgraded to produce 250 MeV energy contribution per station. This involves installii new, higher power, longer pulse klystrons, upgrading klystron modulators to provide these higher voltage, longer klystron beam pulses, and a new interlock and protection system.’ A new VAX based diagnostic system inclu...

متن کامل

NLC Reliability Analysis Notes : Klystron - Modulator System By :

This paper address the reliability and availability issues to be faced in deploying and operating the klystronmodulator assemblies proposed for the Next Linear Collider (NLC). The rf power sources are a major system of the NLC and require a high uptime in order to reach the goal of 0.85 availability. Since the NLC is made up of several systems, not just klystron-modulator assemblies, the availa...

متن کامل

The Design and Performance of 150-MW S-Band Wystrons

As part of an international collaboration, the Stanford Linear Accelerator Center (SLAC) klystron group has designed, fabricated and tested a 60 Hz, 3 W, 150 MW klystron built for Deutsches Elektronen Synchrotron (DESY). A test diode with a 535 kV, 700 A electron beam was constructed to verify the gun operation. The first klystron was built and successfully met design specifications. This paper...

متن کامل

Analyses of Klystron Modulator Approaches for Nlc

Major changes to the Next Linear Collider (NLC) design were facilitated by the experimental testing of the 75 MW X-band klystron at a 3.0 μsec pulse width 1 and new component development allowing the delay line distribution system (DLDS) to operate with eight bins instead of four. This change has a direct effect on the design of the klystron modulator. The general approaches, which are being st...

متن کامل