Characterization of Choroidal Layers in Normal Aging Eyes Using Enface Swept-Source Optical Coherence Tomography

نویسندگان

  • Mehreen Adhi
  • Daniela Ferrara
  • Robert F. Mullins
  • Caroline R. Baumal
  • Kathrin J. Mohler
  • Martin F. Kraus
  • Jonathan Liu
  • Emmerson Badaro
  • Tarek Alasil
  • Joachim Hornegger
  • James G. Fujimoto
  • Jay S. Duker
  • Nadia K. Waheed
  • Zsolt Ablonczy
چکیده

PURPOSE To characterize qualitative and quantitative features of the choroid in normal eyes using enface swept-source optical coherence tomography (SS-OCT). METHODS Fifty-two eyes of 26 consecutive normal subjects were prospectively recruited to obtain multiple three-dimensional 12 x 12 mm volumetric scans using a long-wavelength high-speed SS-OCT prototype. A motion-correction algorithm merged multiple SS-OCT volumes to improve signal. Retinal pigment epithelium (RPE) was segmented as the reference and enface images were extracted at varying depths every 4.13 μm intervals. Systematic analysis of the choroid at different depths was performed to qualitatively assess the morphology of the choroid and quantify the absolute thicknesses as well as the relative thicknesses of the choroidal vascular layers including the choroidal microvasculature (choriocapillaris, terminal arterioles and venules; CC) and choroidal vessels (CV) with respect to the subfoveal total choroidal thickness (TC). Subjects were divided into two age groups: younger (<40 years) and older (≥ 40 years). RESULTS Mean age of subjects was 41.92 (24-66) years. Enface images at the level of the RPE, CC, CV, and choroidal-scleral interface were used to assess specific qualitative features. In the younger age group, the mean absolute thicknesses were: TC 379.4 μm (SD ± 75.7 μm), CC 81.3 μm (SD ± 21.2 μm) and CV 298.1 μm (SD ± 63.7 μm). In the older group, the mean absolute thicknesses were: TC 305.0 μm (SD ± 50.9 μm), CC 56.4μm (SD ± 12.1 μm) and CV 248.6μm (SD ± 49.7 μm). In the younger group, the relative thicknesses of the individual choroidal layers were: CC 21.5% (SD ± 4.0%) and CV 78.4% (SD ± 4.0%). In the older group, the relative thicknesses were: CC 18.9% (SD ± 4.5%) and CV 81.1% (SD ± 4.5%). The absolute thicknesses were smaller in the older age group for all choroidal layers (TC p=0.006, CC p=0.0003, CV p=0.03) while the relative thickness was smaller only for the CC (p=0.04). CONCLUSIONS Enface SS-OCT at 1050 nm enables a precise qualitative and quantitative characterization of the individual choroidal layers in normal eyes. Only the CC is relatively thinner in the older eyes. In-vivo evaluation of the choroid at variable depths may be potentially valuable in understanding the natural history of age-related posterior segment disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Aging and Segmental Choroidal Thickness Measurement using Swept Source Optical Coherence Tomography in Healthy Eyes

PURPOSE To assess and compare choroidal thickness changes related to aging, we determined whether changes are due to thinning of the choriocapillaris plus Sattler's (CS) layer and/or the large vessel layer in healthy eyes using swept-source optical coherence tomography (SS-OCT) at a wavelength of 1,050-nm. METHODS We studied 115 normal eyes of 115 healthy volunteers, all with refractive error...

متن کامل

Analysis of Age-related Choroidal Layers Thinning in Healthy Eyes Using Swept-source Optical Coherence Tomography.

PURPOSE To study the changes in the choroidal layers thickness with age in a healthy population using swept-source optical coherence tomography. METHODS Retrospective data analysis of a subgroup of eyes from a previous single-center, prospective, cross-sectional, noninterventional study. One hundred and sixty-nine healthy eyes were evaluated using swept-source optical coherence tomography. In...

متن کامل

Comparison of choroidal thickness using swept-source and spectral-domain optical coherence tomography in normal Indian eyes

BACKGROUND/AIMS Choroidal thickness measurements are reported to differ between spectral-domain optical coherence tomography (SD-OCT) and swept-source OCT (SS-OCT). The aim of this study was to assess the comparability of choroidal thickness measurements using SS-OCT and SD-OCT devices among normal participants. MATERIALS AND METHODS This was a prospective study of 31 (62 eyes) normal partici...

متن کامل

Age-Dependent Morphologic Alterations in the Outer Retinal and Choroidal Thicknesses Using Swept Source Optical Coherence Tomography

PURPOSE To evaluate the age-dependent morphologic alterations in the outer retina and choroid at the macula using swept-source optical coherence tomography (OCT). METHODS Thirty eyes (30 normal subjects; average age, 49 years) were examined; five (age range, third-eighth decades of life) had refractive errors of ±2 diopters or less and no fundus abnormalities. An Early Treatment Diabetic Reti...

متن کامل

Automatic Measurement of Choroidal Thickness with Swept-Source Optical Coherence Tomography for Clinical Follow-Up in Acute Vogt-Koyanagi-Harada Disease

Background: The course of acute Vogt-Koyanagi-Harada is typically assessed qualitatively using indocyanine green angiography. Swept-source optical coherence tomography may provide a safer, non-invasive, more objective approach to follow up. In this study, we assess the clinical value of the automated measurement capabilities of swept-source tomography to measure choroidal thickness. Design: Pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015