A method for optimal depth of the nasopharyngeal temperature probe: the philtrum to tragus distance
نویسندگان
چکیده
BACKGROUND The nasopharyngeal temperature probe should be placed in the upper nasopharynx to reflect accurate core temperature. However, there have been no studies conducted to predict parameters for the optimal depth of the nasopharyngeal temperature probe. The purpose of this study was to examine the correlation between the optimal depth to the upper nasopharynx and the distance from the philtrum to the tragus and height. METHODS Two hundred patients (100 females and 100 males) were enrolled in the study. The distance from the philtrum to the tragus along the facial curvature was measured, and the optimal depth from the nostril to the upper nasopharynx was evaluated using nasendoscopy. The relationships between the optimal depth to the upper nasopharynx and the distance from the philtrum to the tragus and height were examined. RESULTS The distances from the philtrum to the tragus were 14.4 ± 0.5 cm in females and 15.1 ± 0.6 cm in males (P < 0.01). The depths from the nostril to the upper nasopharynx were 9.4 ± 0.6 cm in females and 10.0 ± 0.5 cm in males (P < 0.01). The correlation coefficients between the depth from the nostril to the upper nasopharynx and the distance to the tragus from the philtrum were 0.43 in females and 0.41 in males (P < 0.01). However, there were very weak correlations and no correlations between height and the depth from the nostril to the upper nasopharynx in females and males, respectively. CONCLUSIONS The depth from the nostril to the upper nasopharynx is correlated weakly with the distance from the philtrum to the tragus. Although the distance from the philtrum to the tragus is not a good predicting parameter for the optimal depth of nasopharyngeal temperature probe placement, subtraction of 5 cm from the distance is helpful to estimate the optimal depth of the nasopharyngeal temperature probe.
منابع مشابه
Estimation of optimal nasotracheal tube depth in adult patients
Background The aim of this study was to estimate the optimal depth of nasotracheal tube placement. Methods We enrolled 110 patients scheduled to undergo oral and maxillofacial surgery, requiring nasotracheal intubation. After intubation, the depth of tube insertion was measured. The neck circumference and distances from nares to tragus, tragus to angle of the mandible, and angle of the mandib...
متن کاملEffect of Pullback Speed and the Distance between the Skin and Vein on the Performance of Endovenous Laser Treatment by Numerical Simulation
Introduction: Endovenous laser treatment (ELT) is a new treatment method for the reflux of the great saphenous vein. A successful ELT is dependent on the selection of optimum parameters required to achieve optimal vein damage while avoiding side effects including skin burns. The mathematical modeling of ELT can be used to understand the process of ELT. This study was conducted to examine the ef...
متن کاملMonte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping
Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...
متن کاملOptimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials
The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...
متن کاملOptimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials
The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...
متن کامل