High risk of misinterpreting liver and spleen stiffness using 2D shear-wave and transient elastography after a moderate or high calorie meal

نویسندگان

  • Maria Kjærgaard
  • Maja Thiele
  • Christian Jansen
  • Bjørn Stæhr Madsen
  • Jan Görtzen
  • Christian Strassburg
  • Jonel Trebicka
  • Aleksander Krag
چکیده

Food intake increases liver stiffness, but it is believed that liver stiffness returns to baseline two hours after a meal. The aim of this study was to investigate the impact of different sized meals on liver stiffness. Liver and spleen stiffness was measured with transient elastography (TE) and real-time 2-dimensional shear wave elastography (2D-SWE). Patients ingested a 625 kcal and a 1250 kcal liquid meal on two consecutive days. We measured liver and spleen elasticity, Controlled attenuation parameter (CAP) and portal flow at baseline and after 20, 40, 60, 120 and 180 minutes. Sixty patients participated, 83% with alcoholic liver disease. Twenty-eight patients had METAVIR fibrosis score F0-3 and 32 patients had cirrhosis. Liver stiffness, spleen stiffness and CAP increased after both meals for all stages of fibrosis. False positive 2D-SWE liver stiffness measurements caused 36% and 52% of patients with F0-3 fibrosis to be misclassified with higher stages of fibrosis after the moderate and high caloric meal. Likewise, 10% and 13% of compensated cirrhosis patients were misclassified with clinically significant portal hypertension after the two meals. We observed similar misclassification rates with TE. After three hours, liver stiffness remained elevated more than 20% from baseline in up to 50% of patients. IN CONCLUSION Liver stiffness, spleen stiffness and CAP increase after a meal across all stages of fibrosis and across elastography techniques. Up to half of patients may be misclassified with higher stages of fibrosis, if they are assessed after less than three hours fasting period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative and noninvasive assessment of chronic liver diseases using two-dimensional shear wave elastography

Two-dimensional shear wave elastography (2D-SWE) is a rapid, simple and novel noninvasive method that has been proposed for assessing hepatic fibrosis in patients with chronic liver diseases (CLDs) based on measurements of liver stiffness. 2D-SWE can be performed easily at the bedside or in an outpatient clinic and yields immediate results with good reproducibility. Furthermore, 2D-SWE was an e...

متن کامل

How many measurements are needed for liver stiffness assessment by 2D-Shear Wave Elastography (2D-SWE) and which value should be used: the mean or median?

AIM To analyze how many measurements are needed for non-invasive assessment of liver stiffness (LS) by means of 2D-Shear Wave Elastography (2D-SWE) and if the use of mean of median values of 2D-SWE measurements is needed. METHODS We evaluated 449 consecutive subjects (with or without chronic liver disease) by means of Transient Elastography (TE) and 2D-SWE. We compared the correlation of LS a...

متن کامل

Assessment of hepatic fibrosis by transient elastography in rheumatoid arthritis patients receiving methotrexate

Background and Aim: Methotrexate (MTX) is commonly used in the treatment of diseases such as rheumatoid arthritis (RA) but, its hepatotoxicity potential, always has been a major concern. The aim of this study is to determine the rate of liver fibrosis by transient elastography (TE) method and its relationship with cumulative dose of MTX and duration of treatment, in rheumatoid arthritis patient...

متن کامل

Shear wave elastography with a new reliability indicator

Non-invasive methods for liver stiffness assessment have been introduced over recent years. Of these, two main methods for estimating liver fibrosis using ultrasound elastography have become established in clinical practice: shear wave elastography and quasi-static or strain elastography. Shear waves are waves with a motion perpendicular (lateral) to the direction of the generating force. Shear...

متن کامل

Liver and spleen transient elastography predicts portal hypertension in patients with chronic liver disease: a prospective cohort study

BACKGROUND To assess correlation between liver or spleen stiffness measurement by transient elastography (TE) and hepatic venous pressure gradient (HVPG) in patients with chronic liver disease as well find optimal and rule in/rule out cut-offs for prognosis of clinically significant (CSPH) and severe (SPH) portal hypertension. METHODS In this prospective study patients with different chronic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017