Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience

نویسندگان

  • Roy Jogiya
  • Andreas Schuster
  • Arshad Zaman
  • Manish Motwani
  • Marc Kouwenhoven
  • Eike Nagel
  • Sebastian Kozerke
  • Sven Plein
چکیده

BACKGROUND The purpose of this study was to establish the feasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion cardiovascular magnetic resonance (CMR) at 3T using local RF shimming with dual-source RF transmission, and to compare it with spoiled gradient echo (TGRE) acquisition. METHODS Dynamic contrast-enhanced 3D bSSFP perfusion imaging was performed on a 3T MRI scanner equipped with dual-source RF transmission technology. Images were reconstructed using k-space and time broad-use linear acquisition speed-up technique (k-t BLAST) and compartment based principle component analysis (k-t PCA). RESULTS In phantoms and volunteers, local RF shimming with dual source RF transmission significantly improved B1 field homogeneity compared with single source transmission (P=0.01). 3D bSSFP showed improved signal-to-noise, contrast-to-noise and signal homogeneity compared with 3D TGRE (29.8 vs 26.9, P=0.045; 23.2 vs 21.6, P=0.049; 14.9% vs 12.4%, p=0.002, respectively). Image quality was similar between bSSFP and TGRE but there were more dark rim artefacts with bSSFP. k-t PCA reconstruction reduced artefacts for both sequences compared with k-t BLAST. In a subset of five patients, both methods correctly identified those with coronary artery disease. CONCLUSION Three-dimensional bSSFP myocardial perfusion CMR using local RF shimming with dual source parallel RF transmission at 3T is feasible and improves signal characteristics compared with TGRE. Image artefact remains an important limitation of bSSFP imaging at 3T but can be reduced with k-t PCA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion MRI at 3 Tesla using local RF Shimming with dual-source RF transmission

Background Three-dimensional myocardial perfusion MRI offers better myocardial coverage than conventionally used two-dimensional methods. bSSFP three-dimensional myocardial perfusion MRI at 3 Tesla potentially offers further improvement of signal characteristics and may enhance the use of three-dimensional myocardial perfusion MRI for clinical application. Methods Twenty-five healthy volunteers...

متن کامل

High-dose dobutamine stress magnetic resonance perfusion imaging at 3.0 Tesla

Background Dobutamine stress magnetic resonance (DSMR-wall motion) has been established as a valuable tool for the detection of inducible wall motion abnormalities. Additional perfusion imaging during DSMR (DSMR-perfusion) was shown to improve sensitivity for the detection of myocardial ischemia. Current experience is based on 1.5T only, mainly due to insufficient image quality of steady state ...

متن کامل

High-dose dobutamine stress SSFP cine MRI at 3 Tesla with patient adaptive local RF shimming using dual-source RF transmission

Background Image quality of cine imaging using steady state free precession (SSFP) sequences at 3T is insufficient due to increased RF-inhomogeneity (B1 field) and the high sensitivity of SSFP sequences to off-resonance artefacts. Recently, the introduction of a dual source RF transmission system with patient-adaptive local RF-shimming has led to a significant improvement of image quality of SS...

متن کامل

Reference values for regional and global myocardial T2 mapping with cardiovascular magnetic resonance at 1.5T and 3T

Methods Between April and July 2014 we recruited 32 healthy subjects (no known cardiovascular risk factors, no previous history of heart disease), aged between 20 and 80yrs. All of them underwent a cardiovascular magnetic resonance (CMR at 1.5T, n=19; CMR at 3T, n= 13) protocol that included steady state free precession (SSFP) cines for measuring ventricular dimensions and function, TFisp 2D T2...

متن کامل

Extended RF shimming: Sequence‐level parallel transmission optimization applied to steady‐state free precession MRI of the heart

Cardiac magnetic resonance imaging (MRI) at high field presents challenges because of the high specific absorption rate and significant transmit field (B1+ ) inhomogeneities. Parallel transmission MRI offers the ability to correct for both issues at the level of individual radiofrequency (RF) pulses, but must operate within strict hardware and safety constraints. The constraints are themselves ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014