XAFS analysis of triiodide ion in solutions.

نویسندگان

  • H Sakane
  • T Mitsui
  • H Tanida
  • I Watanabe
چکیده

Iodine K-edge XAFS of triiodide ions in various solvents were measured at SPring-8 BL01B1 and analyzed. Though the anion takes a linear and symmetric form, the second peak expected from enhanced multiple scatterings can be hardly observed because of its large vibrations. The bond distances and the Debye-Waller factors for the I-I couple vary when protic solvents were used and they were similar when aprotic solvents were used. It was indicated that the larger the Mayers' acceptor number of the solvent is, the larger the Debye-Waller factor is. It was also found that among the aprotic solvents, the larger the Gutmann's donor number is, the smaller the Debye-Waller factor is.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Triiodide Ion Concentration Using UV-Visible Spectrophotometry†

The concentration of iodine species can be measured using several different analysis methods. One of the most wellknown methods involves iodine titration with a thiosulfate solution. Total iodine can be analyzed using spectrometry, such as inductively coupled plasma-atomic emission spectrometry (ICP-AES), atomic absorption spectrometry (AAS) and inductively coupled plasma-mass spectrometry (ICP...

متن کامل

Structural investigation of Pd(II) in concentrated nitric and perchloric acid solutions by XAFS.

XAFS spectra of palladium(II) in concentrated HNO3/HClO4 acid mixtures have been recorded and analyzed. Structural parameters of the Pd(H2O)4(2+) complex and the mixed nitric Pd(NO3)2(H2O)2 complex, for the first time, were determined by the XAFS method. For pure 5 M HClO4 and for mixtures (0-0.3 M HNO3), the XAFS spectra of the 0.02 M Pd solutions are indeed very similar and originated from fo...

متن کامل

Clotrimazole-triiodide ion association as an ion exchanger for a triiodide ion-selective electrode.

A novel triiodide ion-selective electrode based on a clotrimazole-triiodide ion pair as a membrane carrier was prepared. It has a linear response to triiodide from 8 x 10(-6) to 5 x 10(-3) M with a slope of -68.9 mV per decade and a detection limit of 5 x 10(-6) M. The electrode response is independent of the pH of the solution in the pH range 2-9. It has a very short response time and can be u...

متن کامل

Triiodide PVC membrane electrodes based on charge-transfer complexes.

Three new electrodes were prepared by incorporating two different charge-transfer complexes and amino crown ether into plasticized PVC membranes. The electrodes showed Nernstian response to triiodide ion over the activity range from 1.0 x 10(-5) to 1.0 x 10(-1) mol x L(-1) with detection limits at approximately 1.0 x 10(-6) mol x L(-1). The resulting electrodes have fast response times (20-30 s...

متن کامل

Synthesis of a Charge-Transfer Complex of (1,3-Diphenyldihydro-1H-Imidazole-4,5-Dione Dioxide) with Iodide and Its Application to the Development of a Highly Selective and Sensitive Triiodide PVC-Membrane Electrode

In this paper, a novel membrane triiodide sensor based on a charge-transfer complex of (1,3-diphenyldihydro-1H-imidazole-4,5-dionedioxime) with iodine (CTCI) as a membrane carrier is introduced. The best performance was obtained with a membrane containing 30% polyvinylchloride (PVC), 63% dibutylphthalate (DBP), 5% CTCI and 2% hexadecyltrimethylammonium bromide (HTAB). The electrode shows a Nern...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 8 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2001