Development and refinement of a portable electronic device for haematocrit determination

نویسندگان

  • A. J. Groenewald
  • H. Pieters
چکیده

A SMALL PORTABLE ELECTRONIC DEVICE, named a blood electrometer (BEM), was developed to measure packed cell volume, which can be related to haematocrit (Hct). The electronic circuitry is simple and constructed from standard components. Being battery powered, the device is suitable for bedside or field use (‘point-of-care-testing’) without specialized training. The effects of temperature, anticoagulants, lipid content, electrode type and different BEM electronic circuits on measurement accuracy were evaluated. A method for calibrating the instrument with a sodium chloride calibrator was also devised and evaluated for measurement accuracy. The response of the BEM to Hct is non-linear; a binomial regression function was used to fit the non-linear response to provide accurate Hct values from BEM readings over a wide range of measurements. The BEM response curve is sensitive to the anticoagulant type used, but specific binomial functions reduce error to between –3.1% and +3.3% Hct units. Lipids do not significantly affect BEM readings, even at high concentrations of 9.8 mmol/l. We conclude that the BEM can be relied on for acceptably accurate Hct measurements under a variety of conditions, and can be used for the indirect determination of packed cell volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robot...

متن کامل

A Novel Portable Scissors-Type Fruit Picking Device

At present, the fruit picking in most countries still largely relies on manual operation. Manual fruit picking can protect the fruits from damage during the operation process. However, it is time-consuming and labor-intensive, and poses a potential safety risk to the workers while working at heights not reachable. Therefore, a variety of fruit picking machines and platforms have been developed ...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

Point-of-Care Testing for Anaemia in Children Using Portable Haematocrit Meter: A Pilot Study from Southwest Nigeria and Implications for Developing Countries

BACKGROUND Prompt and accurate diagnosis is needed to prevent the untoward effects of anaemia on children. Although haematology analyzers are the gold standard for accurate measurement of haemoglobin or haematocrit for anaemia diagnosis, they are often out of the reach of most health facilities in resource-poor settings thus creating a care gap. We conducted this study to examine the agreement ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009