The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.

نویسندگان

  • Ahmad Separham
  • Bahram Sohrabi
  • Naser Aslanabadi
  • Samad Ghaffari
چکیده

INTRODUCTION Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one. METHODS We performed a randomized trial to compare the two types of stents. Two hundred patients undergoing PCI for de novo lesions were randomly assigned 1:1 to treatment with either biolimus-eluting (BioMatrix) or everolimus -eluting (Xience V) stent. The primary endpoint was a composite of cardiac death, myocardial infarction, and clinically driven target vessel revascularization within 12 months. RESULTS Demographics, clinical, and lesion characteristic were comparable between two groups. The 30-day major adverse car-diac event (MACE) rate was 2% in BioMatrix group versus 0% in Xience group (p > 0.05). After 12 months, the rates of cardiac death (0% in both groups), MI (2% versus 0%, p=0.49) and clinically -driven target vessel revascularization (0% in both groups) were similar for BioMatrix and Xience. No stent thrombosis was reported at 1, 6, 9 or 12 months after intervention in either group. CONCLUSION BES (Biolimus-eluting stent) with biodegradable polymer and EES (Everolimus-eluting stent) with durable polymer appear similar with respect to MACE and stent thrombosis in this patient population. Many studies with longer follow up are needed to define better the role of BES with biodegradable polymer in treatment of coronary artery lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis

OBJECTIVES To investigate the safety and efficacy of durable polymer drug eluting stents (DES) and biodegradable polymer biolimus eluting stents (biolimus-ES). DESIGN Network meta-analysis of randomised controlled trials. DATA SOURCES AND STUDY SELECTION Medline, Google Scholar, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) database search for randomised controlled tr...

متن کامل

Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

BACKGROUND The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. METHODS AND RESULTS Study stents included BMS, paclitaxel-eluting (PES), siroli...

متن کامل

Two-year outcome of a randomized trial comparing second-generation drug-eluting stents using biodegradable or durable polymer.

Two-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Biodegradable or Durable Polymer Recentnetworkmeta-analyseshave raisedconcerns about the safety of biodegradable polymerdrug-eluting stents (BP-DES) compared with durable polymer everolimus-eluting stents (DP-EES).1-3 The NOBORI Biolimus-Eluting vs XIENCE/ PROMUSEverolimus-ElutingStentTrial (NEXT) is a9...

متن کامل

Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular and thoracic research

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2011