Wear Promoted in the Apical Third of Simulated Canals after Instrumentation with Protaper Universal System

نویسندگان

  • Kathrein Tapia da Silva
  • Renata Grazziotin-Soares
  • Orlando Limongi
  • Luis Eduardo Duarte Irala
  • Alexandre Azevedo Salles
چکیده

OBJECTIVE This study evaluated the wear in the apical third of simulate canals after preparation with ProTaper Universal Rotary System. MATERIAL AND METHODS 24 sets of instruments were used in 24 simulated canals in transparent epoxy resin blocks with degree of curvature of either 20 degrees or 40 degrees. The canals were photographed preoperatively and after preparation of the apical stop with ProTaper F3, F4 and F5 instruments. The initial and final images were exported to Adobe Photoshop software and superimposed to detect the root canal wall differences (in mm) between them, in two points located 1 (A) and 5 (B) mm from the point where the working length was established. Data were subjected to analysis of variance to verify the existence of interaction among the factors: canal curvature, instrument size and curve location. Significant level was set at 5%. RESULTS Regardless of the location and the canal curvature, F4 and F5 instruments produced the greatest wear (p<0.05). CONCLUSIONS There was a deviation from the original pathway towards the outside of the root curvature in both analyzed points. All instruments produced canal transportation, but the F4 and F5 instruments produced more than the other instruments, and should thus be used with care in curved canals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the shaping characteristics of Neolix and Protaper Universal systems in preparation of severely-curved simulated canals

BACKGROUND The aim of this in vitro study was to compare the shaping characteristics of two types of nickel-titanium endodontic file systems with regard to the following parameters: Canal straightening, Canal deviation and Instrumentation time. MATERIAL AND METHODS Fifty severely curved canals simulated in resin blocks were prepared to an apical size 25 using Protaper Universal orNeolix syste...

متن کامل

Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software

OBJECTIVE This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. MATERIAL AND METHODS Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone...

متن کامل

Shaping Ability of Reciproc, UnicOne, and Protaper Universal in Simulated Root Canals

The study aimed to compare the shaping effects, preservation of the original curvature, and transportation of the apical foramen of Reciproc (VDW, Munich, Germany), UnicOne (Medin, Nové Město na Moravě, Czech Republic), and Protaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) in simulated root canals. Thirty resin blocks with simulated curved root canals were distributed into three ...

متن کامل

Comparison of WaveOne and ProTaper Universal Preparation Systems in the Amount of Smear Layer/Debris Production: an in-vitro SEM Study

Background and Aim: Debris and the smear layer that remain after root canal preparations may result in failure of root canal therapies. The aim of this study was to compare the smear layer formation and the amount of residual debris following the use of WaveOne and ProTaper rotary files in mesiobuccal root canals of upper first molars by scanning electron microscopy (SEM). Materials and Method...

متن کامل

A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instru...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2009