Dental implants placed in extraction sites implanted with bioactive glass: human histology and clinical outcome.
نویسندگان
چکیده
PURPOSE To evaluate the clinical outcome of implants placed into sites grafted with bioactive glass. MATERIALS AND METHODS Seventeen consecutively treated patients were referred to a private specialist surgical practice for the repair of dentoalveolar defects, and/or ridge maintenance at the site of extraction sockets, prior to implantation. Bioactive glass available in 1 of 2 forms was utilized as an alloplastic grafting material. Bone cores were trephined out at the time of implantation and processed and examined to evaluate the tissue response under the light microscope. Implant mobility, marginal bone levels, and soft tissue health were all evaluated over a 2- to 3-year follow-up period to determine treatment success. RESULTS A total of 40 Astra Tech dental implants were placed. The overall success rate at the end of the study was 88.6% for implants that were in function for a mean period of 29.2 months (22 to 24 months). One patient with 5 successful implants died at 18 months after functional loading. At that time the cumulative success rate was 90%. Another patient who was diagnosed with cancer of the large bowel lost 3 implants. If this patient were excluded from the data, the cumulative success rate increases to 96.8%. Mean marginal bone loss measured 0.5 mm mesially and 0.4 mm distally over a maximum follow-up of 36 months. Human histology demonstrated that connective tissue was seen to exist without any inflammatory response, for up to 6 months. Increasing evidence of bone formation was seen in direct relation to the bioactive glass material beyond this time frame. DISCUSSION The need to repair and augment dentoalveolar defects necessitates the use of autogenous bone or a substitute that may be seen to avoid the additional morbidity of a donor site procedure and without risk of cross infection. The use of bioactive glass has been proposed as a viable bone substitute. The current study draws attention to the long healing time required to achieve even a small amount of new bone incorporation into the graft, as seen histologically. However, the high rate of osseointegration and continued medium-term function of implants placed into these grafted sites would indicate that the use of bioactive glass does not prohibit osseointegration. However, it is likely that the initial integration will have derived from those areas in contact with native bone. CONCLUSION Implants will survive for up to 3 years in sites grafted with bioactive glass, even when such grafts appear to only slowly conduct new bone growth.
منابع مشابه
Comparison of biomaterial implants in the dental socket: histological analysis in dogs.
BACKGROUND Bone graft procedures have been used commonly in buco-maxillo-facial surgery. For this reason, many researchers have evaluated the bone substitutes. PURPOSE The present study evaluated soft and hard tissue reactions to two different hydroxyapatites HAs (synthetic HA and natural HA) and bioactive glass implanted into the sockets immediately after extraction. MATERIALS AND METHODS ...
متن کاملEnhancement of bone regeneration and graft material resorption using surface-modified bioactive glass in cortical and human maxillary cystic bone defects.
PURPOSE Bioactive glass bonds to bone through a calcium phosphate layer that mimics the structure of the mineral phase of bone. Formation of this layer is inhibited in the presence of serum protein. The authors hypothesize that creation of a calcium phosphate layer on the surface of bioactive glass before implantation will enhance bone regeneration and graft material resorption in bone defects....
متن کاملBioactive glass efficacy in the periodontal healing of intrabony defects in monkeys.
The purpose of this study was the histomorphologic analysis of the efficacy of bioactive glass particles with a narrow size range (Biogran) in the periodontal healing of 2-wall intrabony defects in monkeys. The 2-wall defects were made in the mesial area of the left and right second premolars of four monkeys, filled with gutta-percha and, after 15 days, they were debrided and either naturally f...
متن کاملClinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کاملIndigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
BACKGROUND The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation in 14 patients. MATERIALS AND METHODS Bioactive glass and hydroxyapatite formulated and prepared...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2002