Crystalloid Coload Reduced the Incidence of Hypotension in Spinal Anesthesia for Cesarean Delivery, When Compared to Crystalloid Preload: A Meta-Analysis

نویسندگان

  • Hai-Fang Ni
  • Hua-Yue Liu
  • Juan Zhang
  • Ke Peng
  • Fu-Hai Ji
چکیده

Objective To determine whether crystalloid infusion just after intrathecal injection (coload) would be better than infusion before anesthesia (preload) for hypotension prophylaxis in spinal anesthesia for cesarean delivery. Methods We searched PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and other databases for randomized controlled trials comparing coload of crystalloid with preload in parturients receiving spinal anesthesia for cesarean delivery. Primary outcome was intraoperative incidence of hypotension. Other outcomes were intraoperative need for vasopressors, hemodynamic variables, neonatal outcomes (umbilical artery pH and Apgar scores), and the incidence of maternal nausea and vomiting. We used RevMan 5.2 and STATA 12.0 for the data analyses. Results Ten studies with 824 cases were included. The incidence of hypotension was significantly higher in the preload group compared with the coload group (57.8% versus 47.1%, odds ratio [OR] = 1.62, 95% confidence interval [CI] = 1.11-2.37, and P = 0.01). More patients needed intraoperative vasopressors (OR = 1.71, 95% CI = 1.07-2.04, and P = 0.02) when receiving crystalloid preload. In addition, the incidence of nausea and vomiting was higher in the preload group (OR = 3.40, 95% CI = 1.88-6.16, and P < 0.0001). There were no differences in neonatal outcomes between the groups. Conclusions For parturients receiving crystalloid loading in spinal anesthesia for cesarean delivery, coload strategy is superior to preload for the prevention of maternal hypotension.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the timing of administration of crystalloid on maternal hypotension during spinal anesthesia for cesarean delivery: preload versus coload

BACKGROUND Prophylactic fluid preloading before spinal anesthesia has been a routine procedure to prevent maternal hypotension during cesarean delivery. Unlike colloid, timing of infusion of crystalloid may be important because of its short stay in intravascular space. We hypothesized that crystalloid loading just after intrathecal injection compared to preload would be more effective in preven...

متن کامل

Effect of timing of fluid bolus on reduction of spinal-induced hypotension in patients undergoing elective cesarean delivery.

Spinal-induced hypotension remains the most common complication associated with spinal anesthesia for cesarean delivery. Recent evidence indicates that a 20-mL/kg bolus via pressurized infusion system administered at the time of subarachnoid block (SAB) (coload) may provide better prophylaxis than the traditional administration of a 20-mL/kg crystalloid infusion (preload) approximately 20 minut...

متن کامل

Preload or coload for spinal anesthesia for elective Cesarean delivery: a meta-analysis.

BACKGROUND Hypotension following spinal anesthesia for Cesarean delivery is common. Fluid loading is recommended to prevent hypotension, but preload is often ineffective. In non-pregnant patients, coloading has been shown to better maintain cardiac output after spinal anesthesia. The purpose of this meta-analysis was to determine whether the timing of the fluid infusion, before (preload) or dur...

متن کامل

Combined use of crystalloid preload and low dose spinal anesthesia for preventing hypotension in spinal anesthesia for cesarean delivery: a randomized controlled trial.

BACKGROUND AND OBJECTIVE Spinal anaesthesia for caesarean section is commonly associated with hypotension and crystalloid preload is widely recommended. Low-dose spinal appears to cause less hypotension. The aim of this study was to investigate whether the combined use of crystalloid preload and low dose spinal anaesthesia might further reduce the rates of hypotension. METHODS Sixty-two patie...

متن کامل

The effects of an increase of central blood volume before spinal anesthesia for cesarean delivery: a qualitative systematic review.

UNLABELLED We evaluated in this qualitative systematic review the efficacy of increasing central blood volume on the incidence of hypotension after spinal anesthesia for elective cesarean delivery. Randomized controlled trials investigating any method of increasing central blood volume before the initiation of obstetric spinal anesthesia were sought by using MEDLINE (1966-2000), Embase (January...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017