Visual acuity in infants--the effect of variations in stimulus luminance within the photopic range.
نویسندگان
چکیده
The forced-choice preferential looking technique was used to measure 2-month-old infants' visual acuity for black-and-white, square-wave gratings at six luminance values between -1.0 and 3.0 log cd/m2. The results indicated that the infants' acuity was relatively unaffected by variations in luminance above 1 log cd/m2, but was reduced by approximately 1 octave at a luminance of -0.8 log cd/m2. These results are in agreement with the results of adults tested in the same apparatus and with previously published data from adult subjects. Our results suggest that for infants, as for adults, variations in room illumination above 1.0 log cd/m2 have little effect on visual acuity.
منابع مشابه
Night vision in barn owls: visual acuity and contrast sensitivity under dark adaptation.
Barn owls are effective nocturnal predators. We tested their visual performance at low light levels and determined visual acuity and contrast sensitivity of three barn owls by their behavior at stimulus luminances ranging from photopic to fully scotopic levels (23.5 to 1.5 × 10⁻⁶). Contrast sensitivity and visual acuity decreased only slightly from photopic to scotopic conditions. Peak grating ...
متن کاملThe effects of luminance on FPL and VEP acuity in human infants.
Grating acuity was measured in 16-week-old human infants. Three measurement techniques were used: forced-choice preferential-looking (FPL), and two visual-evoked-potential (VEP) techniques. The stimuli were counterphase flickering sinewave gratings with a space-average luminance of -1.0 or 2.0 log cd/m2. Slightly different luminance-dependent changes occur between FPL and VEP acuities, suggesti...
متن کاملMetrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity.
PURPOSE The purpose of this study is to determine the ability of single-value metrics of retinal image quality of the eye to predict visual performance as measured by high (HC) and low (LC) -contrast acuity at photopic (P) and mesopic (M) light levels in eyes with 20/17 and better visual acuity. METHODS Forty-nine normal subjects in good health ranging in age from 21.8 to 62.6 with 20/17 or b...
متن کاملStimulus luminance and the spatial acuity of domestic fowl (Gallus g. domesticus)
The luminance dependence of spatial acuity in domestic fowl was measured directly over stimulus luminances ranging from 0.06 to 57.35 cd m(-2). At the highest luminance, acuity was around 6.5 c deg(-1), in agreement with previous studies in this species. As stimulus luminance decreased, acuity fell with increasing rate to 3.2 c deg(-1) at 0.06 cd m(-2), following the same shape as acuity functi...
متن کاملVisual Function in Older Eyes in Normal Macular Health: Association with Incident Early Age-Related Macular Degeneration 3 Years Later
PURPOSE In older eyes in normal macular health, we examined associations between impaired photopic acuity, mesopic acuity, spatial contrast sensitivity, light sensitivity, and the presence of low luminance deficit (difference between photopic and mesopic acuity) at baseline and incident AMD 3 years later. Associations were compared with an association between delayed rod-mediated dark adaptatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 24 4 شماره
صفحات -
تاریخ انتشار 1983