Transvenous ablation of atrioventricular conduction with a low energy power source.

نویسندگان

  • E Rowland
  • D Cunningham
  • A Ahsan
  • A Rickards
چکیده

A power source modified to increase voltage delivery and minimise arcing (for a given energy) was used for transvenous ablation of atrioventricular conduction to control refractory supraventricular arrhythmias in 14 patients. Twelve had atrial fibrillation or flutter, one had atrioventricular nodal reentry tachycardia, and the other had permanent junctional reentry tachycardia. Despite treatment with 5-7 (median 6) antiarrhythmic drugs symptoms had persisted in all the patients. Cathodal discharges of 0.5-39.5 J were delivered to the distal electrode (in one case in parallel with the middle electrode). In all patients shocks produced complete atrioventricular block; this was permanent in eleven (79%). Four patients required a second procedure. In one patient, only a transient atrioventricular block could be produced and catheter ablation with a conventional power source also failed. In the other two atrioventricular conduction was modified such that previously ineffective treatment produced satisfactory control of heart rate. The cumulative energy delivered to those in whom permanent complete heart block resulted ranged from 3.6 to 97.8 (mean 38.3) J with a mean of three shocks (range 1-7) delivered per patient. During follow up of 1-28 (mean 14) months 11 patients remained in complete heart block and free of arrhythmia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter.

A single suction electrode catheter was used for His bundle electrogram recording. His bundle pacing, and low-energy (20 or 30 J) His bundle ablation in seven dogs. The suction electrode catheter was actively fixed to the atrial endocardium at the His bundle level. Electrophysiologic studies were performed in the control state, immediately after, and late (greater than 40 days) after His bundle...

متن کامل

Transvenous high energy shock for ablating atrioventricular conduction in man. Observations on the histological effects.

Transvenous ablation of atrioventricular conduction by high energy shock through a pacing wire has been used as a method of controlling the ventricular response to rapid atrial arrhythmias. A patient in whom this technique successfully controlled refractory tachycardia was admitted with severe left ventricular impairment five months after the procedure and died. The heart was examined at necrop...

متن کامل

Transvenous catheter cryoablation of the atrioventricular node and visual assessment of freezing of cardiac tissue using intracardiac echocardiography.

We investigated the use of a catheter-based cryoablation system on atrioventricular (AV) junction ablation in dogs. In five dogs, the cryoablation catheter was introduced to the AV junction area in order to create transient high degree or complete AV block. Cryo-freezing energy was applied by lowering the temperature to -75 degrees C for five minutes as a single cycle. This cycle was repeated u...

متن کامل

Catheter interruption of atrioventricular conduction using radiofrequency energy in a patient with transposition of the great arteries.

Percutaneous catheter mapping and radiofrequency ablation of the AV node-His bundle system (with subsequent transvenous endocardial ventricular pacing) were performed on an 18-year-old woman with transposition of the great arteries and intact ventricular septum and chronic arrhythmias 15 years following a Mustard operation. Exclusion of the AV conduction tissue from the systemic venous circulat...

متن کامل

High frequency alternating current ablation of an accessory pathway in humans.

High frequency alternating current ablation of an accessory pathway was performed in a patient with incessant circus movement tachycardia using a right-sided, free wall accessory pathway. Antiarrhythmic drugs, antitachycardia pacing and transvenous catheter ablation using high energy direct current shocks could not control the supraventricular tachycardia. A 7F bipolar electrode catheter with a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 62 5  شماره 

صفحات  -

تاریخ انتشار 1989