Integral Test of Neutron Data and Comparison of Codes by Re-analysis of the SEG and STEK Experiments

نویسندگان

  • K. Dietze
  • M. Ishikawa
چکیده

Sample reactivity measurements performed at the fast-thermal coupled facilities RRR/SEG (RC Rossendorf) and STEK (ECN Petten) have been re-analyzed using the JNC standard route for reactor calculation JENDL-3.2 // SLAROM / CITATION / PERKY. The C/E-values are compared with results obtained with the competitive European scheme JEF-2.2 // ECCO / ERANOS. When using different input libraries, codes, self-shielding treatments, and likewise different energy group structures in the routes, it is very difficult to locate exactly the source of deviations in the C/E-values. Therefore, a cross-wise use of JEF-2.2 with JNC codes was performed to obtain separate information about data and codes. Furthermore, test calculations have been made to investigate special effects. More comparisons of data libraries and routes, desirable in crisscross way, are recommended to overcome specific disadvantages in integral tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental comparison of thermal neutron absorption cross section in nano and micro particles

The neutron collision cross-section is important in neutron use for a specific job, such as neutron therapy or even in nuclear reactors. In calculating computational codes such as MCNP, only information from the neutron-to-mass collision information contained in the computational code library is used, in the case of nanoscale particles in contrast to the mass of materials and / or particulate m...

متن کامل

بررسی امکان استفاده از چشمه های نوترونی رادیوایزوتوپی در نوترون درمانی با بور

  Background : Performing successful BNCT experiments needs a suitable neutron source. Important factors of the neutron beam are flux and energy that are very important in the selection of neutron source. In most centers that use this method for treatment, reactor is a neutron source, which according to characteristics of the reactor appropriated neutrons are very high. High cost of constructin...

متن کامل

The response of Geant4 hadronic models to the study of neutrons produced in proton irradiation to the light materials

Neutron is one of the products of the interaction of high energy protons with light nuclei. Using computational Monte Carlo codes, it is possible to calculate and predict the neutron spectrum, neutron flux, and doses by simulating the system. But the use of different hadronic models in this process can influence the results of these calculations. In this research, the response of the four hadro...

متن کامل

Title Design of light element analysis system in BNCT and every NCT

Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...

متن کامل

Estimation of neutron and gamma dose in the MNSR research reactor

In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001